Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using the
standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone Alarm/Restoral
Codes
UL Listed Commercial and Residential Installations
The installation requirements listed below must
be met for the following grades of service.
Grade A Local
The installation must have a bell UL Listed for mecantile local alarms (AMSECO
MBL10B with model AB-12 bell housing).
The digital communicator must be enabled.
The control panel must be in the Attack Resistant Enclosure
(DSC Model CMC-1 or PC4050CAR).
Grade B Central Station and Police Connect
The installation must have a bell UL Listed for mecantile local alarms (AMSECO
MBL10B with model AB-12 bell housing).
The digital communicator must be enabled.
The control panel must be in the Attack Resistant Enclosure
(DSC Model CMC-1 or PC4050CAR).
Grade C Central Station
The digital communicator must be enabled.
The control panel must be in the Attack Resistant Enclosure
(DSC Model CMC-1 or PC4050CAR).
All Commercial Installations
The entry delay must not exceed 60 seconds
The exit delay must not exceed 60 seconds.
The minimum bell cutoff time is 15 minutes.
Residential Installations
The entry delay must not exceed 45 seconds
The exit delay must not exceed 60 seconds.
The minimum bell cutoff time is 4 minutes.
Home Health Care Signaling Equipment
There shall be at least two keypads, one of either the LCD5500Z or LCD5501Z
and one of the following models, PC5508Z, PC5516Z or PC5532Z.
Each system shall be programmed to activate an audible trouble signal
within 90 seconds upon loss of microprocessor memory. Trouble annuncia-
tion from second keypad.
Programming
The notes in the programming sections describing the system configurations
for UL Listed installations must be implemented.
Control of the Protected Premises
In order to have a UL Certificated system the protected area is to be under the
responsibility of one ownership and management (i.e. one business under one
name). This may be a group of buildings attached or unattached with different
addresses but under the responsibility of someone having mutual interest. The
person of mutual interest is not the alarm installing company.
Bell Location
The alarm sounding device (bell) must be located where it can be heard by the
person or persons responsible for maintaining the security system during the
daily arming cycle.
Protection of the Control Unit
The local control and the local power supply must be protected by one of the
following ways:
The control unit and audible alarm device must be in a protected area which
is armed 24 hours a day.
Each partition shall arm the area protecting the control unit and the audible
alarm device power supply. This may require duplicate protection armed by
each partition. Access to this protected area, without causing an alarm, will
require that all partitions be disarmed.
In all cases described above, the protected area for the control unit must be
programmed as not bypassable.
Casual Users
The installer should caution the user(s) to not give system information to casual
users (e.g. codes, bypass methods, etc. to baby-sitters or service people).
Only the One-Time Use codes should be given to casual users.
User Information
The installer should advise the users and note in the user instruction manual:
Service organization name and telephone number
The programmed exit time
The programmed entry time
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. module failure
(1)13 Water Flow (1)44 Sensor tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station (1)4A Cross Zone Police Code
(1)16 Duct 24 Hour Non-Burglary
(1)17 Flame (1)5A 24 Hour non-Burg
(1)18 Near Alarm (1)51 Gas detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition
SIA Auto Rep
Codes*
Contact ID
Auto Rep
Codes*
Zone Alm/Rest. Zone Alm/Rest.
Delay 1 BA-ZZ/BH-ZZ (1) 3A
Delay 2 BA-ZZ/BH-ZZ (1) 3A
Instant BA-ZZ/BH-ZZ (1) 3A
Interior BA-ZZ/BH-ZZ (1) 3A
Interior Stay/Away BA-ZZ/BH-ZZ (1) 3A
Delay Stay/Away BA-ZZ/BH-ZZ (1) 3A
Delayed 24Hr Fire FA-ZZ/FH-ZZ (1) 1A
Standard 24Hr Fire FA-ZZ/FH-ZZ (1) 1A
24Hr Supervisory US-ZZ/UR-ZZ (3) 8A
24Hr Supervisory Buzzer UA-ZZ/UH-ZZ (1) 3A
24Hr Burg BA-ZZ/BH-ZZ (1) 3A
24Hr Holdup HA-ZZ/HH-ZZ (1) 22
24Hr Gas GA-ZZ/GH-ZZ (1) 5A
24Hr Heat KA-ZZ/KH-ZZ (1) 5A
24Hr Medical MA-ZZ/MH-ZZ (1) AA
24Hr Panic PA-ZZ/PH-ZZ (1) 2A
24Hr Emergency (non-medical) QA-ZZ/QH-ZZ (1) 1A
24Hr Sprinkler SA-ZZ/SH-ZZ (1) 13
24Hr Waterflow WA-ZZ/WH-ZZ (1) 5A
24Hr Freeze ZA-ZZ/ZH-ZZ (1) 5A
24Hr Latching BA-ZZ/BH-ZZ (1) 3A
Interior Delay BA-ZZ/BH-ZZ (1) 3A
Delayed 24Hr Waterflow SA-ZZ/SH-ZZ (1) 1A
Instant 24Hr Waterflow SA-ZZ/SH-ZZ (1) 1A
Auto Verified Fire FA-ZZ/FH-ZZ (1) 1A
24Hr Fire Supervisory FS-ZZ/FR-ZZ (2) AA
Day Zone BA-ZZ/BH-ZZ (1) 3A
Delayed 24Hr Fire (Wireless) FA-ZZ/FH-ZZ (1) 1A
Standard 24Hr Fire (Wireless) FA-ZZ/FH-ZZ (1) 1A
* ZZ = zones 01-64