PC2550 Version 1.2
[14] Zone Definitions for Zones 1 to 8
Page 19
Notes: When defining zones, ASSIGN DELAY ZONES FIRST to zones 1, 2, 3....then assign the other types to
the remaining zones in any order desired.
The maximum delays allowed for UL residential installations are: Entry delay = 45 seconds; Exit delay = 60
seconds. The maximum delays allowed for UL commercial installations are: Entry delay = 60 seconds; Exit
delay = 60 seconds.
Default 1st Digit 2nd Digit
00 Zone 1 0 = Slow, audible 0 = Delay
01
Zone 2 # 1 = Slow, silent 1 = Instant
01 Zone 3 2 = Fast, audible 2 = Interior
01
Zone 4 # 3 = Fast, silent 3 = Home-Away
02
Zone 5 4 = 24 hr...Bell
02
Zone 6 # Not allowed for UL 5 = 24 hr...Bell/Buzzer
02 Zone 7 local installations. # 6 = 24 hr...Buzzer
02
Zone 8 7 = Auxiliary Delay
8 = Day Zone
[15] 1st System Option Code
Page 19
Note: For UL residential installations. When zones are programmed as normally open (not supervised) they
shall be located within 3 feet of the control unit. Other initiating circuits must be end-of-line supervised.
For UL commercial installations, zones must be end-of-line supervised.
Default Zone Light On Zone Light Off
Off
Zone Light 1 ...................... Communication disabled Communication enabled
Off
Zone Light 2 ...................... Restorals on bell timeout Restorals follow zones
Off Zone Light 3 ...................... Alarm display while armed No alarm display/armed
Off
Zone Light 4 ...................... DTMF dialing Pulse dialing
Off
Zone Light 5 ...................... N/C zones EOL resistors zones
Off
Zone Light 6 ...................... Keypad [P]anic audible Silent
On Zone Light 7 ...................... Call 1st phone only Back up to 2nd phone
Off
Zone Light 8 ...................... 16th code = maid's code Normal code
[16] 2nd System Option Code
Page 20
Default Zone Light On Zone Light Off
Off
Zone Light 1 ...................... Partial Closing Identified Not Identified
Off
Zone Light 2 ...................... Master code not changeable Master code changeable
Off Zone Light 3 ...................... Bell squawk enabled * Bell squawk disabled
Off
Zone Light 4 ...................... PC16 OUT enabled PC16 OUT disabled
Off
Zone Light 5 ...................... TLM trouble only TLM audible when armed
Off
Zone Light 6 ...................... 1400Hz Radionics 2300Hz Radionics
Off Zone Light 7 ...................... TLM disabled TLM enabled
Off
Zone Light 8 ...................... Access code req'd for bypass Access code not req'd
* Note: For UL commercial installations, Bell Squawk must be enabled.