Section 8: Programmable Output
Programming
Programmable Output Attributes
Program only the following attributes for the PGM options listed. All others will be ignored. PGM options are programmed in [009],
[010] & [011].
PGM Attribute Defaults (Y = Attribute ON; N = Attribute OFF):
Attribute: 1 2 3 4 5 6 7 8
ON
Not used Not used True Output Follows Timer Code Req. Not used Not used Not used
OFF
——Inverted On / Off No Code Req. ———
PGM Option
[01] Burg. / Fire Bell Y
[02] Future Use
[03] Sensor Reset Y N
[04] 2-Wire Smoke Support (PGM2 only) Y
[05] Armed Status Y
[06] Ready To Arm Y
[07] Kypd Bzz Follow Y
[08] Courtesy Pulse Y
[09] System Trouble Output / Trouble Options) Y Y Y Y Y Y Y Y
[10] System Event / Event Options) Y Y Y Y Y Y Y Y
[11] System Tamper Y
[12] TLM and Alarm Y
[13] Kiss-off Y
[14] Gnd Strt Pulse Y
[15] Remote Op. Y
[16] LINKS1000 Sup. Y
[17] Away Armed Status Y
[18] Stay Armed Status Y
[19] Comm. Output #1, [*][7][1] Y Y Y
[20] Comm. Output #2, [*][7][2] Y Y N
[21] Comm. Output #3, [*][7][3] Y Y N
[22] Comm. Output #4, [*][7][4] Y Y N
[23] Silent 24 Hr (PGM2 only) Y
[24] Audible 24 Hr (PGM2 only) Y
[25] Delayed Burglary & Fire Bell Y
Attribute:
123456 7 8
PGM Option
ON Serv. req. AC Fail TLM Fault FTC Zone Fault Zone Tmp. Zn. Low Bat. Loss of Clock
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled
[09] System Trouble Y Y YYYY Y Y
ON Burg. Evnt. Fire Evnt. Panic Evnt. Med. Evnt. Supv. Evnt. Priority Evnt. Holdup Evnt. Follows Timer*
OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Latched
[10] System Event Y Y YYYYY N