152
Introduction
FEATURES
• Fully featured security system with Trouble
Supervision, Alarm Memory, Master Code and 3
programmable Access Codes, Quick-Arming and
At-Home Arming, Door Chime, 3 one-touch Keypad
Zones, and more
• Digital Communicator compatible receivers and
their formats
- Silent Knight Model 9000: 3/1, 4/1, 4/2 non-
extended, 3/1 extended, 20 bps, 1400 Hz
handshake.
- Ademco Model 685: 3/1, 4/1, 4/2 non-extended,
3/1 extended, 20 bps, 1400 Hz handshake.
- Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended,
3/1 extended, 20 bps, 1400 Hz handshake.
- Radionics Model D6500: 3/1, 4/2 non-extended,
3/1 extended, with or without parity, 1400 and
2300 Hz handshake.
- Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without
parity, 20 bps, 1400 and 2300 Hz handshake.
• 4 End-of-Line Resistor Supervised Zones
• 6 Programmable Zone Types with Silent or Audible
alarms
• Programmable Output with 4 options
• All Installer’s Programming can be done at the
keypad or through downloading
• EEPROM memory retains all programming even
after all power is removed from the control panel
• Advanced static and lightning protection; unique
“Zap-Trac” circuit board design stops damaging
voltages at the wiring terminals, and transient
protection devices are placed in all critical areas for
further protection
SPECIFICATIONS
PC550 Control Panel
• Four fully programmable zones
• Zones are End-of-Line Resistor supervised
• All zones programmable as 24-Hour Fire Alarm
• Maximum zone loop resistance: 100 ohms
• Bell/Siren Output: PTC 3A
• Bell / Siren Alarms: steady and pulsed alarms
• Programmable Output: 50 mA with 4 options
• Auxiliary Power Output:
- 150 mA (Fire and Burglary), 24-hour standby
- 300 mA (Burglary only), 4-hour standby
• Maximum 3 keypads per system
• Required Battery: 12 V
DC, 4 Ah sealed lead-acid type
- Standby @ 150 mA auxiliary output: 24 hours
- Standby @ 300 mA auxiliary output: 4 hours
• Required Transformer: 16 V
AC, 40 VA
• Panel dimensions: 10" high x 8" wide x 3" deep (254
x 208 x 76 mm)
• Panel Colour: light beige
SL-40 Keypad
• 12-key keypad
• Three one-touch Zones: [F], [A], [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
• All new slimline design
• Keypad dimensions: 4.75" high x 2.75" wide x 1.2"
deep (120mm x 70mm x 30mm)
• Keypad Color: Designer White with Grey display
PC500RK Keypad
• 12-key keypad
• Three one-touch Zones: [F], [A], [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
• Keypad dimensions: 4.5" high x 4.5" wide x 1" deep
(114mm x 114mm x 25.4mm)
• Keypad Color: Mist
PC500RK APS Keypad
• 10-key keypad
• One one-touch Zone: [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
• Keypad dimensions: 4.5" high x 4.5" wide x 1" deep
(114mm x 114mm x 25.4mm)
• Keypad Color: Mist
[10] Opening and Closing Reporting Codes Page 11
For single digit reporting codes, enter [0] as the second digit.
Closing, Access Code 1 Enter [
∗
1
∗
] (HEX A) to transmit a “0” (zero = 10 pulses)
Closing, Access Code 2
Closing, Access Code 3
Closing, Access Code 4
Opening, Access Code 1
Opening, Access Code 2
Opening, Access Code 3
Opening, Access Code 4
[11] Maintenance and Priority Codes Page 11
[P] Key Alarm
[A] Key Alarm
[F] Key Alarm
Battery Trouble
Battery Restore
Periodic Test Code
[12] Downloading Access Code Page 11
Default
0505
This code allows the panel to confirm that a valid downloading computer is requesting access to
the panel.
[13] Maintenance and Priority Codes Page 11
Fire Trouble
Fire Trouble Restore
AC Trouble
AC Trouble Restore
WWW.DIYALARMFORUM.COM
Kommentare zu diesen Handbüchern