Introduction
FEATURES
Fully featured security system with Trouble
Supervision, Alarm Memory, Master Code and 3
programmable Access Codes, Quick-Arming and
At-Home Arming, Door Chime, 3 one-touch Keypad
Zones, and more
Digital Communicator compatible receivers and
their formats
- Silent Knight Model 9000: 3/1, 4/1, 4/2 non-
extended, 3/1 extended, 20 bps, 1400 Hz
handshake.
- Ademco Model 685: 3/1, 4/1, 4/2 non-extended,
3/1 extended, 20 bps, 1400 Hz handshake.
- Sescoa Model 3000: 3/1, 4/1, 4/2 non-extended,
3/1 extended, 20 bps, 1400 Hz handshake.
- Radionics Model D6500: 3/1, 4/2 non-extended,
3/1 extended, with or without parity, 1400 and
2300 Hz handshake.
- Sur-Gard Model MLR2-DG: 3/1, 4/1, 4/2, without
parity, 20 bps, 1400 and 2300 Hz handshake.
4 End-of-Line Resistor Supervised Zones
6 Programmable Zone Types with Silent or Audible
alarms
• Programmable Output with 4 options
All Installer’s Programming can be done at the
keypad or through downloading
EEPROM memory retains all programming even
after all power is removed from the control panel
Advanced static and lightning protection; unique
“Zap-Trac” circuit board design stops damaging
voltages at the wiring terminals, and transient
protection devices are placed in all critical areas for
further protection
SPECIFICATIONS
PC550 Control Panel
Four fully programmable zones
Zones are End-of-Line Resistor supervised
• All zones programmable as 24-Hour Fire Alarm
Maximum zone loop resistance: 100 ohms
• Bell/Siren Output: PTC 3A
• Bell / Siren Alarms: steady and pulsed alarms
• Programmable Output: 50 mA with 4 options
• Auxiliary Power Output:
- 150 mA (Fire and Burglary), 24-hour standby
- 300 mA (Burglary only), 4-hour standby
• Maximum 3 keypads per system
Required Battery: 12 V
DC, 4 Ah sealed lead-acid type
- Standby @ 150 mA auxiliary output: 24 hours
- Standby @ 300 mA auxiliary output: 4 hours
• Required Transformer: 16 V
AC, 40 VA
Panel dimensions: 10" high x 8" wide x 3" deep (254
x 208 x 76 mm)
Panel Colour: light beige
SL-40 Keypad
12-key keypad
• Three one-touch Zones: [F], [A], [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
All new slimline design
• Keypad dimensions: 4.75" high x 2.75" wide x 1.2"
deep (120mm x 70mm x 30mm)
• Keypad Color: Designer White with Grey display
PC500RK Keypad
12-key keypad
• Three one-touch Zones: [F], [A], [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
Keypad dimensions: 4.5" high x 4.5" wide x 1" deep
(114mm x 114mm x 25.4mm)
• Keypad Color: Mist
PC500RK APS Keypad
10-key keypad
• One one-touch Zone: [P]
• 3 Status Lights: Ready, Armed, System
• 4 Zone Lights
Keypad dimensions: 4.5" high x 4.5" wide x 1" deep
(114mm x 114mm x 25.4mm)
• Keypad Color: Mist
[10] Opening and Closing Reporting Codes Page 11
For single digit reporting codes, enter [0] as the second digit.
Closing, Access Code 1 Enter [
1
] (HEX A) to transmit a “0” (zero = 10 pulses)
Closing, Access Code 2
Closing, Access Code 3
Closing, Access Code 4
Opening, Access Code 1
Opening, Access Code 2
Opening, Access Code 3
Opening, Access Code 4
[11] Maintenance and Priority Codes Page 11
[P] Key Alarm
[A] Key Alarm
[F] Key Alarm
Battery Trouble
Battery Restore
Periodic Test Code
[12] Downloading Access Code Page 11
Default
0505
This code allows the panel to confirm that a valid downloading computer is requesting access to
the panel.
[13] Maintenance and Priority Codes Page 11
Fire Trouble
Fire Trouble Restore
AC Trouble
AC Trouble Restore