PowerSeries PC1616/PC1832/PC1864 version 4.1Installation GuideNote to Installer:Center pages contain important end user information. Leave with End Us
PowerSeries - PC1616/PC1832/PC18648Section 3: ProgrammingThis section provides the information necessary to program all required features for a basic
Section 3: Programming93.5 Viewing ProgrammingLED and LCD5501Z KeypadsLCD KeypadThe keypad will immediately display all the information programmed wh
PowerSeries - PC1616/PC1832/PC186410Section 4 – Programming DescriptionsThe following is a brief description of the features and options available in
Section 4 – Programming Descriptions11Section [005] System TimesAfter entering Section [005], enter the 2-digit subsection number for the desired part
PowerSeries - PC1616/PC1832/PC186412Section [012] Keypad LockoutThe system can be programmed to ‘lockout’ keypads if a series of incorrect user or ins
Section 4 – Programming Descriptions13Section [014] Second System Option CodeSection [015] Third System Option CodeSection [016] Fourth System Option
PowerSeries - PC1616/PC1832/PC186414Section [017] Fifth System Option CodeSection [018] Sixth System Option CodeSection [019] Seventh System Option Co
Section 4 – Programming Descriptions15Section [020] Keypad Zone AssignmentEnter the two-digit zone number to be assigned to each keypad assigned to a
PowerSeries - PC1616/PC1832/PC186416Section [165] Maximum Dialing AttemptsProgram the Maximum Dialing Attempts before the panel will generate a Failur
Section 4 – Programming Descriptions17Section [175] Auto-Arm Postpone TimerProgram the time, in minutes, that the system will postpone automatic armin
Table of ContentsSection Description Page11.11.21.31.41.51.61.71.81.91.10Installation & Wiring...
PowerSeries - PC1616/PC1832/PC186418Section [311] to [318] Partition Account NumbersProgram the Partition Account Number for each active partition (Se
Section 4 – Programming Descriptions19Section [380] First Communicator Option CodeSection [381] Second Communicator Option CodeSection [382] Third Com
PowerSeries - PC1616/PC1832/PC186420Section [401] First Downloading Option CodeSection [402] Downloading Computer Phone NumberThe Downloading Computer
Section 4 – Programming Descriptions21PGM Output Option [01], [03] to [08], [11] to [22], [25]PGM Output Option [19] to [22]PGM Output Option [09]PGM
PowerSeries - PC1616/PC1832/PC186422Section [701] First International Option CodeSection [702] Second International Option CodeSection [703] Delay Bet
Section 4 – Programming Descriptions23Section [900] Special Installer InstructionsSection [900]: Display Panel VersionOnly available with LCD5500 or P
PowerSeries - PC1616/PC1832/PC186424Section [993] to [999]: Factory Default Module/PanelThe following Sections can be used to factory default a module
Section 5: Programming Work Sheets25Section 5: Programming Work Sheets5.1 Index to Programming Work SheetsProgramming Option Page[000] Keypad Enrollme
PowerSeries - PC1616/PC1832/PC1864265.2 Programming Worksheets Shaded programming sections indicate minimum programming trerquirementsSIA FAR CP-01 de
5.2 Programming Worksheets27[005] System Times For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds (Defa
Section 1: Installation & Wiring1Section 1: Installation & WiringThis Installation Guide provides the basic installation, wiring and programmi
PowerSeries - PC1616/PC1832/PC186428Programmable Output Options01 Residential Burglary and Fire Bell Output 15 Remote Operation (DLS-3 Support)02 For
DSC PowerSeries Alarm System User GuideAbout Your Security SystemYour DSC Security System has been designed to provide you with the greatest possi-ble
Download complete User manual from www.dsc.comEmergency KeysPress the (F), (A) or (P) key for 2 seconds to generate a Fire, Auxiliary orPanic ala
DSC PowerSeries Alarm System User Guide6-digit user code or press [4] to delete the user code. After the user code is pro-grammed or deleted, enter a
Download complete User manual from www.dsc.com’Split level arrangement: Smoke detectors are required where shown. Smoke detec-tors are optional where
5.2 Programming Worksheets29[013] First System Options[014] Second System Options[015] Third System Options[016] Fourth System OptionsOpt Def ON OFF1R
PowerSeries - PC1616/PC1832/PC186430[017] Fifth System Options[018] Sixth System Options[019] Seventh System Options - For Future UseKeypad Zone Assig
5.2 Programming Worksheets31[023] Tenth System Options[030] Zone Loop Response (Zones 1-8)Opt Def ON OFF1RFire Key Beeps Only9RFire Key Beeps and Soun
PowerSeries - PC1616/PC1832/PC186432[101]-[164] Zone Attributes Zone Attribute Defaults (Y = Option ON; N = Option OFF): Bold entries are opposite for
5.2 Programming Worksheets33 Section Zone # Zone Audible/ Steady/ Chime Bypass Force* Swing Tx. Delay Wireless Cross ZnType** Silent Pulsed No No No N
PowerSeries - PC1616/PC1832/PC186421.1 Keybus WiringThe 4-wire KEYBUS (red, black, yellow and green) is the communication connection between the contr
PowerSeries - PC1616/PC1832/PC186434System Timers[165] Maximum Dialing Attempts to Each Telephone Number Default 005 I_______I_______I_______I Valid e
5.2 Programming Worksheets35No Activity Arming Timers - Default is [000] for all partitionsSection Partition[191] 1 I_______I_______I_______I Valid e
PowerSeries - PC1616/PC1832/PC186436Communications[304] Call Waiting Cancel String (6 Digits) - This feature is activated in Section 382 Opt 4I_______
5.2 Programming Worksheets37[324]-[327] Alarm Restoral Reporting Codes, Zones 01-64 Section[324] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zone 06 Zo
PowerSeries - PC1616/PC1832/PC186438[334]-[337] Tamper Restoral Reporting Codes, Zones 01-64 Section[334] Zone 01 Zone 02 Zone 03 Zone 04 Zone 05 Zo
5.2 Programming Worksheets39 [350] Communicator Format Options Default04I_______I_______I 1st Telephone Number04I_______I_______I 2nd Telephone Numbe
PowerSeries - PC1616/PC1832/PC186440Call Direction Options[351]-[358] Alarm/Restore Communicator Call Directions [359]-[366] Tamper/Restore Communicat
5.2 Programming Worksheets41[377] Communication VariablesDefault 003 I___0__I__0__I___1__I Swinger Shutdown (Alarms and Rest) 001-014 Transmissions003
PowerSeries - PC1616/PC1832/PC186442[382] Third Communicator Options*This option must remain OFF for SIA-FAR installations.** A Call Waiting Cancel on
5.2 Programming Worksheets43[501]- [554]Programmable Output Attributes Program only the following attributes for the PGM options listed. All others wi
Installation3PC1616/1832/1864 Wiring DiagramPC BoardCabinetStand OffPrimary:120VAC/60Hz.Secondary: 16.5VDC 40VADSCPTD 1640UClass II TransformerNOTE: D
PowerSeries - PC1616/PC1832/PC186444Section PGM Output 1 2 3 4 5 6 7 8#Type*Main Board[501] 1 ( )I________I I________| I________| I________|
5.2 Programming Worksheets45INTERNATIONAL PROGRAMMING[700] Automatic Clock Adjust Default = 60 |________|_________| Valid Entries 00-99 Secon
PowerSeries - PC1616/PC1832/PC186446Special Installer Functions[900] Panel Version Displayed[901] InstallerWalk Test Mode Enable/Disable [902] Module
Appendix A: Reporting CodesAppendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA format reporting codes. For more info
PowerSeries - PC1616/PC1832/PC1864[345]-[346] Auxiliary Power Trouble/Rest.Aux voltage supply trouble/restoral MA/R (3) 12 YP-00/YQ-00[345] TLM Failur
Appendix B: UL Listed Commercial and Residential InstallationsAppendix B: UL Listed Commercial and Residential InstallationsThe installation requireme
PowerSeries - PC1616/PC1832/PC1864Appendix C: SIA False Alarm ReductionSIA FeatureProgramming SectionComments Range/Default Require-mentExit Time[005]
Appendix D: Troubleshooting GuideAppendix D: Troubleshooting GuideTesting:• Power up system• Program options as required (See Programming Section)NOT
PowerSeries - PC1616/PC1832/PC1864Trouble Cause TroubleshootingTrouble [1] Service Required Press [1] to determine specific tro
Appendix D: Troubleshooting GuideTrouble Cause TroubleshootingTrouble [2] AC FailureNo AC at panel AC input terminalsVerify voltage measured across AC
PowerSeries - PC1616/PC1832/PC186441.5 AUX Power WiringThe control panel can provide a maximum of 700mA of current for modules, powered detectors, rel
PowerSeries - PC1616/PC1832/PC1864Trouble Cause TroubleshootingTrouble [5] Zone Fault (Cont.)One or more wireless devices have not checked in within t
NOTES
Note to InstallersThis warning contains vital information. As the only individual in contact with system users, it is yourresponsibility to bring each
FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your authority to use this eq
Section 2: User Commands5Section 2: User CommandsAny system keypad can be used to program or perform any keypad command. LED keypads use status and z
PowerSeries - PC1616/PC1832/PC18646[4][2] Trouble DisplayRefer to Appendix D – Trouble Conditions, for troubleshooting assistance and a detailed descr
Section 2: User Commands7[4][6] – User FunctionsPress [4][6] followed by the Master Code, then press the number corresponding to the following functio
Kommentare zu diesen Handbüchern