DSC MAXSYS PC4010 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheitszugriffskontrollsysteme DSC MAXSYS PC4010 herunter. DSC 4010 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1
Table of Contents
Introduction........................................................................................................ 2
About Your Security System .............................................................................. 2
Fire Detection ............................................................................................... 2
Monitoring .................................................................................................... 2
General System Operation .......................................................................... 3
Keypad LED Displays ....................................................................................... 3
System Master Menu Functions ........................................................................ 3
Partition Status Enunciator ................................................................................ 4
Global Keypads ................................................................................................. 4
What is a Global Keypad? ........................................................................... 4
How to use a Global Keypad? ..................................................................... 4
Display of Alarms/Bypassed Zones .................................................................. 9
Auto-bypass/Home-Away Arming ..................................................................... 9
Partition Keypads ............................................................................................ 10
Keypad Zones............................................................................................ 10
Arming ........................................................................................................ 10
Disarming ................................................................................................... 12
User Programming Commands []+[5]+[Access Code] ......................... 13
Programming Additional Access Codes Using
a System Master Code or a Supervisory Code ....................................... 15
Zone Bypassing []+[1] ............................................................................ 17
Trouble Display []+[2] ............................................................................. 18
Alarm Memory Display []+[3] .................................................................. 21
Sensor Reset []+[4] when disarmed ....................................................... 21
User Functions Command []+[6]+[Access Code] ................................. 21
Walk Test []+[6]+[Walk Test Code] when disarmed .............................. 23
Door Strike []+[7] or []+[7]+[Access Code] ........................................ 24
Installer’s Programming Commands []+[8]+[Installer’s Code] .............. 24
“At-Home” Arming []+[9]+[Access Code] .............................................. 24
Quick Arm []+[0] ..................................................................................... 25
Quick Exit []+[0] when armed ................................................................. 25
Keypad Lockout .............................................................................................. 25
Fire Safety in the Home ................................................................................... 25
Household Fire Safety Audit............................................................................ 25
Family Escape Planning .................................................................................. 26
Maintenance .................................................................................................... 27
Limited Warranty.............................................................................................. 27
Appendix A
List of Available ASCII Characters ............................................................ 28
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Table of Contents

1Table of ContentsIntroduction... 2About Your Sec

Seite 2 - ✎Important Note

10Partition KeypadsKEYPAD ZONESAll Fire, Auxiliary and Panic keys are only functional if they have beenprogrammed by the installer. The installer shou

Seite 3 - System Master Menu Functions

11If a multi partition access code is entered the keypad will display themessage(0) TO ARM < >(Partition Label) R .The lower right hand corner o

Seite 4 - Global Keypads

12DISARMINGEnter the premises through the designated exit-entry door. The keypadbuzzer will be on. Go to the keypad and enter the 4 digit or 6 digitac

Seite 5

13USER PROGRAMMING COMMANDS[✱]+[5]+[ACCESS CODE]The [✱][5][Access Code] command is used to program the Master Codesand regular access codes.The first

Seite 6

14• One-Time Use Codes are used to allow infrequent users of the system,such as service personnel, to arm the system. When the system is armedusing a

Seite 7

15PROGRAMMING ADDITIONAL ACCESS CODES USING A SYSTEMMASTER CODE OR A SUPERVISORY CODE1 Press [✱] then [5] to enter the User Programming Commands; thek

Seite 8

16For example, if you press the [4] key once, the letter ‘J’ will appearabove the cursor on the display. Press the [4] key again, the nextletter ‘K’ w

Seite 9 - Auto-bypass/Home-Away Arming

17ZONE BYPASSING[✱]+[1]A bypassed zone will not cause an alarm. If a zone is bypassed the panelmay be armed even if the zone is open. Use zone bypassi

Seite 10 - Partition Keypads

18While the system is disarmed, bypassing can be used to temporarily silencethe door chime feature on a zone. Simply bypass the zone that the doorchim

Seite 11

19Aux Supply Troub - An Aux trouble is generated if the aux fuse on the mainpanel opens, or if the Aux or SW Aux terminals are overloaded.TLM Trouble

Seite 12 - Disarm Partition

2IntroductionThe LCD4500 keypad provides easy to understand English languageinformation about the status of your security system and makes dailyoperat

Seite 13

20COMBUS Low Pwr - Modules are not getting enough voltage from theCOMBUS. Check for proper connection of COMBUS, or the COMBUS needsto be repowered. S

Seite 14

21Zn LwBatt Fault - This trouble condition will occur when a wireless zonehas a low battery condition. To view which zone has the trouble press the[✱]

Seite 15

22Items [0], [1], [5] and [6] turn on and off various functions. To enable ordisable these functions, press the [✱] key to toggle “Y ”or “N” on the

Seite 16

23[3] Keypad Setup allows the user to adjust the backlighting and contrast ofthe LCD4500 keypad. When this function is selected, the keypad setupmenu

Seite 17 - STU7 VWX8 YZ90

24[1] Local Walk Test is selected the keypad will sound 3 quick beeps andreturn to the normal disarmed display. The user can then test eachdetector on

Seite 18

25QUICK ARM[✱]+[0]Entering [✱] [0] is accepted as a valid arming code when the “Quick Arm”feature is activated. This command is often used when indivi

Seite 19

26Family Escape PlanningThere is often very little time between the detection of a fire and the time itbecomes deadly. It is thus very important that

Seite 20

LIMITED WARRANTYDigital Security Controls Ltd. warrants the originalpurchaser that for a period of twelve months fromthe date of purchase, the product

Seite 21

28Appendix ALIST OF AVAILABLE ASCII CHARACTERS

Seite 22

3GENERAL SYSTEM OPERATIONYour security system is made up of a PC4010 and one or more LCD4500and various detectors and sensors. The DSC control panel w

Seite 23

4[2] Set System Date programs the system’s calendar. Enter 6 digits, thefirst two digits are the month, the middle 2 digits are the day, and the lastt

Seite 24

5• Single Partition Access CodeENTER YOURACCESS CODEThe user enters a valid single partition access code.[*] TO VIEW < >SYSTEM TROUBLESThis mess

Seite 25 - Keypad Lockout

6After all open zones have been viewed the user will be given the option tobypass all open zones. To bypass all open zones press the [✱] key.(PARTITIO

Seite 26 - Maintenance

7[*] TO VIEW < >SYSTEM TROUBLESThis message will be displayed if there are troubles on the system and theinstaller has enabled the option “GLB K

Seite 27 - LIMITED WARRANTY

8ENTER YOURACCESS CODEAfter the exit delay in progress message has been displayed the keypadwill return to this message.(PARTITION LABEL) <>* FO

Seite 28 - Appendix A

9ACCESSING(Partition label)When a keypad is loaned to another partition this message will be displayed for3 seconds. Once the keypad is loaned to anot