Section 2: Advanced Programming
••Refer to section xx and page xx in the Installation Guide. 3
[006] Installer’s Code (2.2.2 “Access Codes” on page 20••)
[007] Master Code (2.2.2 “Access Codes” on page 20••)
[008] Maintenance Code (2.2.2 “Access Codes” on page 20••)
NOTE: Valid codes are 0000-9999. Enter AAAA to disable maintenance code.
[012] Keypad Lockout Options
(2.2.13 “Keypad Options” on page 34••)
NOTE: If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
[013] First System Option Code
**The Temporal Three Fire Signal option must be used for Household Fire installations.
[014] Second System Option Code
Default: 5555
I_______I_______I_______I_______I
Default: 1234
I_______I_______I_______I_______I
Default: AAAA
I_______I_______I_______I_______I
Default
000
I_______I_______I_______I
Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I
Lockout Duration (001-255 minutes)
Default Option ON OFF
Section/
Page #••
OFF
I________I
1 Hardwired Zones are Normally Closed Hardwired Zones use End-of-Line Resistors 1.2.5 / 6
OFF
I________I 2-3 For future use
OFF
I________I 4 Tampers/Faults Do Not Sound as Open Tampers/Faults Sound as Open 2.2.9 / 27
OFF
I________I 5 For future use
ON
I________I 6 Audible Exit Fault Enabled Audible Exit Fault Disabled 2.2.7 / 25
ON
I________I 7 Event Buffer Follows Swinger Shutdown Event Buffer Logs Events Past shutdown 2.3.17 / 53
ON
I________I 8 Temporal Three Fire Signal Enabled** Standard Pulsed Fire Signal 2.2.8 / 26
Default Option ON OFF
Section/
Page #••
OFF
I________I 1 Arm / Disarm Bell Squawk enabled Arm / Disarm Bell Squawk disabled 2.2.5 / 24
OFF
I________I
2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 2.2.7 / 25
OFF
I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 2.2.7 / 25
OFF
I________I 4 Bell Squawk On Entry Delay No Bell Squawk On Entry Delay 2.2.7 / 25
OFF
I________I
5 Bell Squawk On Trouble No Bell Squawk On Trouble 2.2.9 / 27
ON
I________I
6 Audible Exit with Urgency Silent Exit Delay 2.2.7 / 25
OFF
I________I
7 Exit Delay Termination Enabled Exit Delay Termination Disabled 2.2.7 / 25
OFF
I________I 8 Fire Bell is Continuous Fire Bell Follows Bell Cut-off 2.2.8 / 26