Basic Programming:
5
System Times and Codes
[005] System Times
[006] Installer’s Code
Default
5555
I_______I_______I_______I_______I
[007] Master Code
Default
1234 I_______I_______I_______I_______I
[008] Maintenance Code
Default
AAAA I_______I_______I_______I_______I
Programmable Output Options
01 Residential Burglary and Fire Bell Output 14 Ground Start Pulse
02 For Future Use 15 Remote Operation (DLS-3 Support)
03 Sensor Reset [*][7][2] 16 LINKS1000 Support (PGM1 only)
04 2 Wire Smoke Support (PGM 2 only) 17 Away Armed Status
05 System Armed Status 18 Stay Armed Status
06 Ready To Arm 19 Command Output #1 ([*][7][1])
07 Keypad Buzzer Follow Mode 20 Command Output #2 ([*][7][2])
08 Courtesy Pulse 21 Command Output #3 ([*][7][3])
09 System Trouble Output (with Trouble options) 22 Command Output #4 ([*][7][4])
10 System Event [Strobe (with Event options)] 23 24 Hour Silent Input
11 System Tamper (all sources: zones, keypad, modules) 24 24 Hour Audible Input
12 TLM and Alarm 25 Delayed Fire and Burglary Output
13 Kissoff Output
NOTE: Output types [03] and [20] cannot be used together on the same system.
[009] PGM1 and PGM2 Output Programming (Main Panel)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
19
I_______I_______I PGM 1 10 I_______I_______I PGM 2
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208)
NOTE: Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default Default
01 I_______I_______I PGM 3 (main panel/PC5208)* 01 I_______I_______I PGM 7 (PC5208)
01 I_______I_______I PGM 4 (main panel/PC5208)* 01 I_______I_______I PGM 8 (PC5208)
01 I_______I_______I PGM 5 (PC5208) 01 I_______I_______I PGM 9 (PC5208)
01 I_______I_______I PGM 6 (PC5208) 01 I_______I_______I PGM 10 (PC5208)
NOTE: These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on
the PC5208. If you use both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output,
and PGM4 will work the same as the second PC5208 output.
NOTE: Valid entries for Entry Delay is between 001-255, valid entries for Exit Delay is between 001-255.
[01] Partition 1 Entry/Exit times [05] Partition 5 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 1
045 I___I___I___I Entry Delay 1 045 I___I___I___I Entry Delay 1
120
I___I___I___I Exit Delay
120
I___I___I___I Exit Delay
[02] Partition 2 Entry/Exit times [06] Partition 6 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 1
045 I___I___I___I Entry Delay 1 045 I___I___I___I Entry Delay 1
120
I___I___I___I Exit Delay
120
I___I___I___I Exit Delay
[03] Partition 3 Entry/Exit times [07] Partition 7 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 1
045 I___I___I___I Entry Delay 1 045 I___I___I___I Entry Delay 1
120
I___I___I___I Exit Delay
120
I___I___I___I Exit Delay
[04] Partition 4 Entry/Exit times [08] Partition 8 Entry/Exit times
030
I___I___I___I Entry Delay 1
030
I___I___I___I Entry Delay 1
045 I___I___I___I Entry Delay 1 045 I___I___I___I Entry Delay 1
120
I___I___I___I Exit Delay
120
I___I___I___I Exit Delay
[09] Bell Cut-Off Timer (All Partitions)
004
I___I___I___I Enter 3 digits from 001-255
Kommentare zu diesen Handbüchern