DSC PC 580 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software DSC PC 580 herunter. PC 0580 Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Programming Work sheets
29
Keypad Programming
[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)
NOTE: This must be done at each keypad requiring programming.
[0] Slot [Valid entries are 11-18; i.e. enter [11] for slot 1, [12] for slot 2, etc.]
[1] Function Key 1 Assignment (Valid entries are 00-17)
[2] Function Key 2 Assignment (Valid entries are 00-17)
[3] Function Key 3 Assignment (Valid entries are 00-17)
[4] Function Key 4 Assignment (Valid entries are 00-17)
[5] Function Key 5 Assignment (Valid entries are 00-17)
Function Key Options:
Slot Function Function Function Function Function
Key 1 Key 2 Key 3 Key 4 Key 5
LED Defaults 11 03 04 06 14 16
LCD Defaults 18 03 04 06 14 16
KEYPAD 1
I________I________I I________I I________I I________I I________I I________I
KEYPAD 2 I________I________I I________I I________I I________I I________I I________I
KEYPAD 3 I________I________I I________I I________I I________I I________I I________I
KEYPAD 4 I________I________I I________I I________I I________I I________I I________I
KEYPAD 5 I________I________I I________I I________I I________I I________I I________I
KEYPAD 6 I________I________I I________I I________I I________I I________I I________I
KEYPAD 7 I________I________I I________I I________I I________I I________I I________I
KEYPAD 8 I________I________I I________I I________I I________I I________I I________I
Basic Programming
Zone Definitions
NOTE:Keypads must be installed to use 24-hour Buzzer zones.
NOTE:Keypad zones are assigned in section [020]. Zone Attributes are assigned in sections [101] - [132]. Zone assignment is in
sections [202] - [205].
[001] Zone 1-8 Definitions (Section 5.2 “Zone Programming on page 15)
Default Default
01 I_______I_______I Zone 1 00 I_______I_______I Zone 5
03
I_______I_______I Zone 2 00 I_______I_______I Zone 6
04
I_______I_______I Zone 3 00 I_______I_______I Zone 7
04
I_______I_______I Zone 4 00 I_______I_______I Zone 8
00 Null Key 08 [*][1] Bypass Mode 16 [*][0] Quick Exit
01 For future use 09 [*][2] Trouble Display 17 [*][1] Reactivate Stay/Aways
02 For future use 10 [*][3] Alarm Memory 18 For future use
03 Stay Arm 11 [*][5] User Programming 19 For future use
04 Away Arm 12 [*][6] User Functions 20 For future use
05 [*][9] No-Entry Arm 13 Command Output #1 [*][7][1] 21 For future use
06 [*][4] Chime On / Off 14 Command Output #2 [*][7][2]
07 [*][6][——][4] System Test 15 For future use
00 Null Zone (Not Used) 10 24 Hour Supervisory Buzzer 20 24 Hour Freeze
01 Delay 1 11 24 Hour Burglary 21 24 Hour Latching Tamper
02 Delay 2 12 24 Hour Holdup 22 Momentary Keyswitch Arm
03 Instant 13 24 Hour Gas 23 Maintained Keyswitch Arm
04 Interior 14 24 Hour Heating (N/C zone) 24 LINKS Answer
05 Interior, Stay/Away 15 24 Hour Medical 25 Interior Delay
06 Delay, Stay/Away 16 24 Hour Panic 87 Delay 24 Hour Fire (Wireless)
07 Delayed 24 Hour Fire (Hardwired) 17 24 Hour Emergency 88 Standard 24 Hour Fire (Wireless)
08 Standard 24 Hour Fire (Hardwired) 18 24 Hour Sprinkler
09 24 Hour Supervisory 19 24 Hour Water
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1 - Basic Programming

Programming Work sheets29Keypad Programming[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)NOTE: This must be done at each keypad

Seite 2

38[353] Wireless Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)I_______I_______I 1. Wireless

Seite 3 - Programming Work sheets

Programming Work sheets39[370] Communication VariablesDefault Section Page #003 I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (001-014

Seite 4

40Downloading Options[401] First Downloading Option Code (Section 5.10 “Downloading” on page 20)Default Option ON OffOFF I_______I 1 Answering

Seite 5 - Advanced System Programming

Programming Work sheets41Special Installer Functions[901] Installer Walk Test Mode Enable / Disable (Section 5.30 “Walk Test (Installer)” on page 26)

Seite 6 - PGM Option

42Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA for-mat reporting codes. For more information on reporting code

Seite 7 - Communicator Programming

Reporti ng Codes43Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when usingth

Seite 8

44Appendix B: Programming LCD KeypadsIf you have an LCD5500Z Keypad, additional programming is required for proper operation. The following is a descr

Seite 9

Programming LCD Keypad s45[61] Second User Display MaskDefault Option ON OFFOFF I_______I 1 Installer Programming prompt ON Installer Programming p

Seite 10

30NOTE:Zones 9-32 are only available for wireless zones.[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming” on page 15)Default Default00 I___

Seite 11

Programming Work sheets31[012] Keypad Lockout Options (Section 5.21 “Keypad Lockout Options” on page 24)NOTE:If Keypad Lockout is active, the panel c

Seite 12 - Module Programming*

32[017] Fifth System Option CodeDefault Option ON Off Section Page #ON I________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses Access Codes 5

Seite 13 - Special Installer Functions

Programming Work sheets33Advanced System ProgrammingZone Attributes (Section 5.3 “Zone Attributes” on page 16)Zone Attribute Defaults (Y = Option ON;

Seite 14 - Appendix A: Reporting Codes

34[115] 15 ( ) I________I I________| I________| I________| I________| I________| I________| I________I[116] 16 ( ) I________I I____

Seite 15 - Alarm/Restoral Codes

Programming Work sheets35Section PGM Output 1 2 3 4 5 6 7 8# Type*[141] 1 ( ) I________I I________| I________| I________| I________| I_______

Seite 16

36Alarm Restoral Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix A)Section[324] Zone 1 Zone 2 Zo

Seite 17

Programming Work sheets37Closing (Arming) Reporting Codes, Access Codes 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 18, & Appendix