Installation
Manual
WARNING
This manual contains information on limitations regarding product use and function and information on the
limitations as to liability of the manufacturer. The entire manual should be carefully read.
This panel will not operate if installed outside of North America. See section 1.1 for details.
Software Version 2.3 / DLS-1 v6.7 and up
See Back Cover for New Features in Version 2.3
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - Installation

InstallationManualWARNINGThis manual contains information on limitations regarding product use and function and information on the limitations as to l

Seite 2 - Limited Warranty

6NOTE:Only one NC contact can be connected to each zone.Wiring multiple detection devices or contacts on a single loopis not allowed.The following cha

Seite 3 - Table of Contents

Getting Started: 2.11 Keypad Zones7Assigning Keypad ZonesWhen using keypad zone inputs, each input used must beassigned a zone number in Installer’s P

Seite 4 - PC580 Wiring Diagram

8Section 3: Keypad CommandsUse any system keypad to enter commands and/or programthe PC580 security system. The LED keypad uses functionand zone indic

Seite 5 - 1.1 Specifications

Keypad Commands: 3.4 [*] Commands9Activate Stay/Away ZonesIf the system is armed in stay mode, the [*][1] command canbe used to activate the stay/away

Seite 6 - 1.3 Out of the Box

10[*][5] Programming Access CodesThere are 37 access codes available to the user. They are:Access code (40)... One master code Acces

Seite 7 - Section 2: Getting Started

Keypad Commands: 3.5 Function Keys11press [#] to exit. This feature can be accessed on LED key-pads by pressing and holding the [*] key.[*][7] Command

Seite 8 - 2.5 Keypad Assignment

12[12] [*][6] User Functions: A valid master code must alsobe entered.[13] [*][7][1] Command Output Option #1: A validaccess code may need to be ent

Seite 9 - 2.8 Zone Wiring

13Section 4: How to ProgramThe following section of the manual describes the Installer’sProgramming function and how to program the various sec-tions.

Seite 10 - 2.11 Keypad Zones

144.4 Programming Toggle Option SectionsSome programming sections contain several toggle options.The panel will use zone lights 1 through 8 to indicat

Seite 11

15Section 5: Program DescriptionsThe following section explains the operation of all programma-ble features and options and provides a summary of all

Seite 12 - Section 3: Keypad Commands

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual in contact with system users, it is you

Seite 13

16the Bell Cutoff time expires (Section [005] “System Times”), oruntil a code is entered. (See 5.13 “Bell” on page 22.)NOTE:If a second Fire type zone

Seite 14

Program Descriptions: 5.4 Assigning Keypad Zones17and bell for a zone once its swinger limit has beenreached. (See 5.19 “Swinger Shutdown” on page 24.

Seite 15 - 3.5 Function Keys

18Reporting codes can be one or two digits and can use HEXdigits (A through F). For a complete description of reportingcodes which can be programmed a

Seite 16 - “[*][2] Trouble Display”

Program Descriptions: 5.9 Communicator – Reporting Formats195.9 Communicator – Reporting FormatsEach communication telephone number can be programmedt

Seite 17 - Section 4: How to Program

20Hex [C] - simulates the [#] key on a touch tone telephoneHex [D] - forces the panel to search for dial toneHex [E] - two second pauseHex [F] - marks

Seite 18 - 4.5 Viewing Programming

Program Descriptions: 5.11 PGM Output Options21NOTE:Only ONE of options [03] Sensor Reset and [20] [*][7][2] Command Output Option #2 may be programme

Seite 19 - 5.2 Zone Programming

22[18] Stay Armed StatusWhen the system is armed in the Stay mode, the PGM outputwill activate at the beginning of the exit delay. The outputdeactivat

Seite 20 - 5.3 Zone Attributes

Program Descriptions: 5.14 Test Transmission235.14 Test TransmissionTo ensure that the communication link with the central stationis functioning prope

Seite 21 - 5.5 Communicator – Dialing

24Quick Arm Enable . . . . . . . . . . . . . . . . . . . .Section [015]: [4]Quick Exit Enable . . . . . . . . . . . . . . . . . . . .Section [015]: [

Seite 22

Program Descriptions: 5.22 Keypad Blanking255.22 Keypad BlankingIf the Blank Keypad When Not in Use option is enabled, thepanel will turn off all ligh

Seite 23

iTable of ContentsSection 1: System Introduction 11.1 Specifications ...11.2 Add

Seite 24 - 5.11 PGM Output Options

26(Downloading Telephone Number) . . . . . . . . . . Section [490]Communicator Call Direction Options. . . Section [361]-[368]Call LINKS as well as La

Seite 25

27Section 6: Programming WorksheetsFor the RecordCustomer: ___________________________________________________________________________________________

Seite 26 - 5.13 Bell

28Zone Programming SummaryZone programming can be found in sections [001] - [004], [101] - [132], [020] and [202] - [205]. Use this area to record a

Seite 27 - 5.17 Arming/Disarming Options

Programming Worksheets29Keypad Programming[000] Keypad Enrollment (Section 2.5 “Keypad Assignment” on page 4)NOTE: This must be done at each keypad r

Seite 28 - 5.21 Keypad Lockout Options

30NOTE:Zones 9-32 are only available for wireless zones.[002] Zone 9-16 Definitions (Section 5.2 “Zone Programming” on page 15)Default Default00 I___

Seite 29 - 5.25 Keypad Tampers

Programming Worksheets31[012] Keypad Lockout Options (Section 5.21 “Keypad Lockout Options” on page 24)NOTE:If Keypad Lockout is active, the panel ca

Seite 30 - 5.30 Walk Test (Installer)

32[017] Fifth System Option CodeDefault Option ON Off Section Page #ON I________I 1 WLS Key Does Not Use Access Codes* WLS Key Uses Access Codes 5.1

Seite 31 - For the Record

Programming Worksheets33Advanced System ProgrammingZone Attributes (Section 5.3 “Zone Attributes” on page 16)Zone Attribute Defaults (Y = Option ON;

Seite 32 - Zone Programming Summary

34[116] 16 ( ) I________I I________| I________| I________| I________| I________| I________| I________I[117] 17 ( ) I________I I____

Seite 33 - Basic Programming

Programming Worksheets35Section PGM Output 1 2 3 4 5 6 7 8# Type*[141] 1 ( ) I________I I________| I________| I________| I________| I________

Seite 34

iiPC580 Wiring Diagram

Seite 35 - Programming Worksheets

36Alarm Restoral Reporting Codes, Zones 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)Section[324] Zone 1 Zone 2 Zo

Seite 36

Programming Worksheets37Closing (Arming) Reporting Codes, Access Codes 1-32 (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A

Seite 37 - Advanced System Programming

38[353] Wireless Maintenance Reporting Codes (Section 5.8 “Communicator – Reporting Codes” on pg. 17, & Appendix A)I_______I_______I 1. Wireless

Seite 38 - PGM Option

Programming Worksheets39[370] Communication VariablesDefault Section Page #003 I_______I_______I_______I Swinger Shutdown (Alarms and Rest) (001-014 T

Seite 39 - Communicator Programming

40Downloading Options[401] First Downloading Option Code (Section 5.10 “Downloading” on page 20)Default Option ON OffOFF I_______I 1 Answering m

Seite 40

Programming Worksheets41Module Programming[801] PC5400 Printer Module Programming Please refer to your PC5400 Installation Manual for installation and

Seite 41

42Appendix A: Reporting CodesThe following tables contain Contact ID and Automatic SIA for-mat reporting codes. For more information on reporting code

Seite 42

Reporting Codes43Table2: Contact ID Zone Alarm/Restoral Event Codes (as per ADEMCO):Program any of these codes for zone alarms/restorals when usingthe

Seite 43

44Appendix B: Programming LCD KeypadsIf you have an LCD5500Z Keypad, additional programming is required for proper operation. The following is a descr

Seite 44 - International Programming

Programming LCD Keypads45[61] Second User Display MaskDefault Option ON OFFOFF I_______I 1 Installer Programming prompt ON Installer Programming pro

Seite 45 - Special Installer Functions

1Section 1: System Introduction1.1 SpecificationsDownloading Software Support• PC580 v2.3 uses DLS-1 v6.7 and up.Flexible Zone Configuration• Four ful

Seite 47 - (1)4A Cross Zone Police Code

FCC COMPLIANCE STATEMENTCAUTION: Changes or modifications not expressly approved by DigitalSecurity Controls Ltd. could void your authority to use thi

Seite 48

©1998 Digital Security Controls Ltd.1645 Flint Road, Downsview, Ontario, Canada M3J 2J6(416) 665-8460 • Fax (416) 665-7498 • 1-800-387-3630www.dscgrp.

Seite 49

21.2 Additional DevicesIn addition to the information below, see the back cover for aDSC module compatibility table.PC5132 Wireless ReceiverThe PC5132

Seite 50

3Section 2: Getting StartedThe following sections provide a thorough description of howto wire and configure devices and zones.2.1 Installation StepsR

Seite 51

4Programmable Output Terminals – PGM1 and PGM2Each PGM output is designed so that when activated by thepanel, the terminal will switch to groundPGM1 c

Seite 52 - PC580 Module Compatibility

Getting Started: 2.6 Supervision55. Press [#] twice to exit installer programming. After assigning all keypads, perform a supervisory reset byentering