DSC PC580 - V2.3 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Software DSC PC580 - V2.3 herunter. DSC PC580 - V2.3 Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Installation Manual

Installation ManualLCD55O1Z32-433 NA version 4.1WARNING: Please refer to the System Installation Manual forinformation on limitations regarding produc

Seite 2 - Table of Contents

8 Receiver ProgrammingS E C T I O N 3Enroll & Program DevicesThis section describes how to enroll and program:• wireless devices using zo

Seite 3 - Introduction

95. The device is now enrolled on the system. Record the serial number and theassigned zone number in the programming worksheets in the back of this m

Seite 4 - Installation

101. At a system keypad, enter [✱][8][Installer’s code].2. Enter programming section [804].3. Enter programming section [59] for keys assigned to part

Seite 5 - 1.5 Enrolling the Keypad

11E N R O L L & P R O G R A M D E V I C E S3.5 Deleting Wireless DevicesTo remove a wireless device from the system, follow the guideline for a

Seite 6 - 1.6 Downloading

124.1 Program Zones and PartitionsNow that you have enrolled the wireless devices, you should complete all zoneprogramming on the system. Although the

Seite 7 - Keypad Programming

13To program the wireless supervisory window:1. Enter [✱][8][Installer Code] to enter Installer Programming.2. Enter [804] to enter into Receiver Prog

Seite 8 - 2.6 Door Chime Options

14O T H E R P R O G R A M M I N GTo restore the PC5132 programming to the factory default settings, perform thefollowing:1. Enter [✱][8] [Installer’s

Seite 9 - Door Chime Sounds

15S E C T I O N 5Testing & Mounting5.1 Test the placement of the WLS904P, WLS906,WLS907, WLS912, WLS914 and the WLS925LIt is very impor

Seite 10 - Receiver Programming

165.2 Test WLS909 & WLS919 ReceptionThe wireless key (WLS909) cannot be tested using the module placement test describedabove. To ensure that the

Seite 11 - Enroll Wireless keys

17S E C T I O N 6Additional Notes6.1 Trouble ConditionsThe control panel always watches for possible trouble conditions. If a trouble conditi

Seite 12 - Command Output Activation

T A B L E O F C O N T E N T STable of ContentsIntroduction 1Section 1: Installation 21.1 Unpacking ...

Seite 13 - 3.5 Deleting Wireless Devices

18S E C T I O N 7Troubleshooting1. When I enter the 2-digit zone number when adding a wireless device,the keypad gives me a long beep.You ca

Seite 14 - Other Programming

19S E C T I O N 8Programming Worksheets[000] Keypad Programming1. Enter [*][8][Installer’s code]2. Enter [000] to go to keypad programming[0]

Seite 15 - 4.4 RF Jam Detect Zone

20[*] Door Chime Sound Programming1. Enter [*][8][Installer’s code][*]2. Enter 2-digit zone number [01] - [32], then select door chime sound option [1

Seite 16

21[804] Wireless Expansion Programming• 6-digit entry is required. See Section 3.1 “A note on Electronic Serial Numbers”for details on programming 6-d

Seite 17 - Testing & Mounting

22P R O G R A M M I N G W O R K S H E E T SWireless Key Serial NumbersDefault = 000000[41] Key 01l_____l_____l_____l_____l_____l

Seite 18 - Installation Sheet

23P R O G R A M M I N G W O R K S H E E T SDefault = 00Default = 00Default = 00Default = 00Default = 00Partition 1 Wireless Key

Seite 19 - Additional Notes

24P R O G R A M M I N G W O R K S H E E T S[84] Zone Device Supervision Options (17-24) Zone Device Supervision Options (17-24

Seite 20 - Troubleshooting

25P R O G R A M M I N G W O R K S H E E T S[91]Wireless Keys (1-8) Partition AssignmentsWireless Keys (1-8) Partition Assignment

Seite 21 - Programming Worksheets

26A P P E N D I X AGuidelines for Locating Smoke DetectorsExperience has shown that all hostile fires in family living units generate smoke

Seite 22

LIMITED WARRANTYDigital Security Controls Ltd. warrants the original purchaser that for a period of twelve months from the date of purchase, theproduc

Seite 23 - Zone Serial Numbers

1IntroductionThe LCD5501Z32-433 keypad combines a standard PC5132 receiver with anLCD5501Z keypad that presents system status using an LCD-style displ

Seite 24 - Wireless Key Serial Numbers

WARNING Please Read CarefullyNote to InstallersThis warning contains vital information. As the only individual incontact with system users, it is your

Seite 26

©2000 Digital Security Controls Ltd.Toronto, Canada1-800-387-3630 • www.dsc.comPrinted in Canada 29005206 R002This device complies with RSS-210 of

Seite 27

21.1 UnpackingThe LCD5501Z32-433 package includes the following parThe LCD5501Z32-433 package includes the following parThe LCD5501Z32-433 package inc

Seite 28 - A P P E N D I X A

3I N S T A L L A T I O N1.4 Applying PowerOnce all wiring is complete, apply power to the control panel:1. Connect the battery leads to the

Seite 29 - LIMITED WARRANTY

4I N S T A L L A T I O NIf both modules do not show on the keypad, one of the following conditions may bepresent:• the keypad is not connec

Seite 30 - WARNING Please Read Carefully

52.1 Programming the KeypadThere are several programming options available for the LCD5501Z32-433 keypad.These are described below. Record all your pr

Seite 31

62.4 Alarms Displayed While Armed OptionYou can disable the display of alarms on the keypad when the system is armed. Thedisplay of alarms is enabled

Seite 32 - Toronto, Canada

71. Enter [*][8][Installer’s code]2. Enter [000] to go to keypad programming3. Enter section [6].4. To turn the options on or off, press [6] or [7]:[6