PANELS, KEYPADS & MODULES
5
▲ return to contents
POWERSERIES
Some products are not available in all countries. Contact your local distributor for details.
PowerSeries
TM
Control Panel Overview
Features
PC585 PC1616 PC1832 PC1864
Number Of Built-In Panel Zones 4 6 8 8
Total Zones Supported 32 32 32 64
Keypad Zone Expansion Yes Yes Yes Yes
Hardwired Zone Expansion No Yes Yes Yes
Hardwired Zones - 16 (1 x PC5108) 32 (3 x PC5108) 64 (7 x PC5108)
Wireless Zone Expansion Yes Yes Yes Yes (32 Wireless)
Addressable Zone Expansion No Yes Yes Yes (32 Addressable)
Number of Keypads 8 8 8 8
Number of Wireless Receivers 4 4 4 4
On-Board PGM Outputs
PGM 1 = 50 mA
PGM 2 = 50mA
PGM 1 = 50 mA
PGM 2 = 300mA
PGM 1 = 50 mA
PGM 2 = 300mA
PGM 1, 3, 4 = 50 mA
PGM 2 = 300mA
Number of Main Panel
Low-Current PGM Outputs
2 1 1 3
Number of Main Panel
High-Current PGM Outputs
- 1 1 1
PGM Expansion -
8 x 50 mA (PC5208)
4 x 500 mA (PC5204)
8 x 50 mA (PC5208)
4 x 500 mA (PC5204)
8 x 50 mA (PC5208)
4 x 500 mA (PC5204)
Number of Additional
Low-Current PGM Outputs
- 8 8 8
Number of Additional
High-Current PGM Outputs
- 4 4 4
Number of Access Codes 32+ Master Code 47+ Master Code 71+ Master Code 94+ Master Code
Number of Partitions 1 2 4 8
Panel Event Buffer 128 500 500 500
Phone Line Supervision Yes Yes Yes Yes
Siren Supervision Yes Yes Yes Yes
Bell Output 12 V / 700 mA (cont) 12 V / 700 mA (cont) 12 V / 700 mA (cont) 12 V / 700 mA (cont)
SIA CO-01 Compliant No Yes Yes Yes
Event-Initiated Personal Paging Yes Yes Yes Yes
Upload/Download Support Yes Yes Yes Yes
Direct-Connect (PC Link)
Downloading Support
Yes Yes Yes Yes
DLS2002SA End-User
Downloading Support
- Yes Yes Yes
Internet Alarm Communications No Yes Yes Yes
Audio Alarm Verification No Yes Yes Yes
GSM Alarm Communications Yes Yes Yes Yes
Battery Required 4 Ah / 7 Ah / 14 Ahr 4 Ah / 7 Ah / 14 Ahr 4 Ah / 7 Ah / 14 Ahr 4 Ah / 7 Ah / 14 Ahr