PC1404 v1.0
Installation Guide
WARNING: This manual contains information on limitations regarding product use and function
and information on the limitations as to liability of the manufacturer. The entire manual should
be carefully read.
Seitenansicht 0
1 2 3 4 5 6 ... 75 76

Inhaltsverzeichnis

Seite 1 - Installation Guide

PC1404 v1.0Installation GuideWARNING: This manual contains information on limitations regarding product use and function and information on the limita

Seite 2 - IMPORTANT NOTE!

PC14044Keybus Terminals – AUX+, AUX-, YEL, GRN The Keybus is used by the panel to communicate with modulesand vice versa. Each module has four Keybus

Seite 3 - 6PRNH'HWHFWRUV

2 Installation2.5 Current Ratings – Modules & AccessoriesIn order for the PC1404 system to operate properly, the poweroutput capabilities of the

Seite 4 - Limited Warranty

PC14046Single End Of Line (EOL) Resistors (5600)To enable panel detection of single end of line resistors, Section[013], Options [1] and [2] must be

Seite 5 - Table of Contents

2 Installation2.11 Fire Zone Wiring All 4-wire smoke detectors must be wired according to the fol-lowing diagram:All 2-wire smoke detectors must be w

Seite 6 - PC1404 Wiring Diagram

PC140483 Keypad CommandsUse any compatible keypad to enter commands and/or program the PC1404 security system. The LED keypad uses function and zonein

Seite 7 - 1 Introduction

3 Keypad Commands9[][7][x] Command Functions 1–4[][8][Installer Code] Installer Programming[][9][User Code] No-Entry Arming[][0] Quick Arm (disar

Seite 8 - AC, 40VA

PC140410[*][3] Alarm MemoryWhen Disarmed, press [*] then [3] to enter the alarm memory mode. The "Memory" light will flash and any alarm cau

Seite 9 - 2 Installation

3 Keypad Commands11[7] Bell Squawk upon Arming/Disarming – This attribute is used to determine whether an access code should generate an arming/dis-ar

Seite 10 - Telephone Line Wiring

PC140412Additional Keypad FunctionsThe following additional keypad functions are available:Event Buffer: View the 128-event panel bufferBrightness Con

Seite 11 - 2.9 Zone Wiring

4 Programming134 ProgrammingThe PC1404 can be programmed using the following methods:4.1 Installer ProgrammingThe following section of the manual desc

Seite 12 - 2.10 Zone Doubling

i6$)(7<,16758&7,216IRU6(59,&(3(56211(/WARNING: When using equipment connected to the TELEPHONE NETWORK, there are basic safety instruct

Seite 13 - 2.13 Keypad Zones

PC140414If you are using a pulse communications format, a decimal zero [0] does not transmit. Programming a zero [0] tells the panel not to sendany pu

Seite 14 - 3 Keypad Commands

5 Programming Worksheets155 Programming Worksheets5.1 Index to Programming Worksheets and Descriptions Programming Option

Seite 15

PC1404 165.2 Programming WorksheetsKeypad Partition/Slot and Function Key Programming[000] Function Key ProgrammingNote: Keypad enrollment must be don

Seite 16 - [*][5] Program User Codes

5 Programming Worksheets17[005] System Times[009] Main Board PGM Output Programming (PGM 1 & 2)[010] PC5208 PGM Output ProgrammingValid entries fo

Seite 17 - [*][6] – User Functions

PC1404 18[011] PC5204 PGM Output Programming[012] Keypad Lockout OptionsNote: If Keypad Lockout is active, the panel CANNOT be disarmed with a keyswi

Seite 18

5 Programming Worksheets19[017] Fifth System Options[018] Sixth System Options[020] Keypad Zone Assignments[022] Ninth System Options[023] Tenth Syste

Seite 19 - 4 Programming

PC1404 20[030] Zone Loop Response Options[101]-[108] Zone Attributes [101] Zone 1 Attributes [102] Zone 2 Attributes [103] Zone 3 Attributes [104]

Seite 20 - [1][][3], [0]:

5 Programming Worksheets21[170] PGM Output Timer Default 005 I_______I_______I_______I Valid entries are 001-255 seconds[175] Auto-arm Postpone TimerD

Seite 21 - 5 Programming Worksheets

PC1404 22[176] Cross Zone/Police Code Timer Default 060 I_______I_______I_______I Valid entries are 000-255 seconds/minutes[181] Auto-Arm Time of DayD

Seite 22 - 5.2 Programming Worksheets

5 Programming Worksheets23[329] Priority Alarm and Restore Reporting Codes[330] Tamper Reporting Codes, Zones 01-08 [334] Tamper Restore Reporting Cod

Seite 23 - Default Default

LL*XLGHOLQHVIRU/RFDWLQJ6PRNH&2'HWHFWRUVThe following information is for general guidance only and it is recommended that local fire co

Seite 24 - *][6] + Installer Prog

PC1404 24[343] Opening (Disarming) Reporting Codes, Access Codes 17-32[344] Miscellaneous Opening (Disarming) Reporting Codes[345] Maintenance Alarm R

Seite 25 - [023] Tenth System Options

5 Programming Worksheets25[367] Opening/Closing Communicator Call Directions[375] System Maintenance Alarm/Restore Communicator Call Directions[376] S

Seite 26 - Zone Attribute Defaults

PC1404 26[382] Third Communicator Options[383] Fourth Communicator OptionsDLS Downloading[401] Downloading Option Codes[402] DLS Downloading Computer’

Seite 27 - Default EU

5 Programming Worksheets27[404] Panel ID Code (Enter 6 Hexadecimal Digits)[405] Answering Machine Double-Call Timer Default 060 I_______I_______I_____

Seite 28 - Reporting Codes

PC1404 28Zone Follower PGM requires 2 programming sections for attributes: the normal PGM attribute Sections [501-514] and Sections [551-564] for zone

Seite 29

5 Programming Worksheets29[601] Closing (Arming) Reporting Codes, Access Codes 33-40[605] Opening (Disarming) Reporting Codes, Access Codes 33-40INTER

Seite 30

PC1404 30Programming PK5500 KeypadsIf you have an PK5500 keypad, additional programming is required for proper operation. All LCD programming is done

Seite 31 - Opt Def. ON OFF

Programming PK5500 Keypads31[001]-[008] Zone Labels[071] First User Display MaskDefaultZ o n e _ _ _ _ 1 _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ __BBBB_BBB

Seite 32 - DLS Downloading

PC1404 32[072] Second User Display Mask[073] Downloaded LCD Message DurationDefault: 003 _BBBB_BBBB_BBBB_ (Valid entries are 000-255, 000=Unlimited

Seite 33 - Attribute:

Programming PK5500 Keypads33[080] PGM Terminal 1[082] Local PGM Output Activation Time[101] Partition 1 Label[102]–[108] Partition 2–8 Labels[120]–[12

Seite 34

LLLLimited WarrantyDigital Security Controls warrants the original purchaser that for a period of twelve months from the date of purchase, the product

Seite 35 - INTERNATIONAL PROGRAMMING

PC14045.3 Programming Descriptions3URJUDPPLQJ'HVFULSWLRQVThe following is a description of the programming features and options available in t

Seite 36 - Programmable Labels

5.3 Programming DescriptionsZone ProgrammingZones 1-8 are enabled by default. Disable unused zones or enable additional zones in Section [001] Zone

Seite 37

PC1404[08] Standard 24-hr Fire Zone (hardwired) Note: Do not wire Fire zones on keypad zone terminals if the DEOL supervision option is enabled for

Seite 38 - [077] Second Keypad Options

5.3 Programming DescriptionsA bypass of this zone type must be manually removed.With an audible alarm active, using the keyswitch when disarmed is t

Seite 39

PC1404[005] System TimesEnter Section [005] then Subsection [01] to program the Entry Delay 1, Entry Delay 2 and Exit Delay for the system. Entries

Seite 40 - 5.3 Programming Descriptions

5.3 Programming Descriptions09 System Trouble. This PGM output switches to ground when any of the selected Troubles are detected. The output de-acti

Seite 41 - [001] Zone Definitions

PC1404[012] Keypad Lockout OptionsThis section determines how the keypad function operates. The panel can be configured to "lockout" keypa

Seite 42

5.3 Programming Descriptions[013] First System Options[014] Second System OptionsOption Description[1] Zone Loop TypeON: Normally Closed Loops. All

Seite 43

PC1404[015] Third System Options[016] Fourth System Options[7]Exit Delay Termina-tionExit Delay Termination Enabled. The exit delay will be reduced

Seite 44 - [008] Maintenance Code

5.3 Programming Descriptions[017] Fifth System Options [018] Sixth System Options [3] Keypad BlankingON: Blank Keypad When Not Used. If no keys are

Seite 45

ivTable of ContentsSafety Instructions for Service Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46 - [012] Keypad Lockout Options

PC1404[020] Keypad Zone AssignmentEnter the two-digit zone number to be assigned to each keypad assigned to a specific slot. Only one keypad can be

Seite 47 - [014] Second System Options

5.3 Programming Descriptions[030] Zone Loop Response OptionsFast loop response for the onboard zones is programmable using Installer Programming Sec

Seite 48 - Annunciation

PC1404[168] Daylight Savings Time BeginsExample: E.g., Set the clock 1 hour ahead at March 5th, 2006 at 2:00am.1. Enter Section [168]. 2. Program t

Seite 49

5.3 Programming Descriptions[199] Auto-Arming Pre-Alert TimerIn this section, program the time (in minutes) for the Auto-Arming Pre-Alert time. This

Seite 50 - [020] Keypad Zone Assignment

PC1404[330]-[334] Tamper/Restore Reporting Codes, Zones 01-8These reporting codes are used by the communicator to transmit zone tampers and restores

Seite 51 - Daylight Savings Time

5.3 Programming DescriptionsFire Trouble & RestoreAn open circuit or any Low Sensitivity, Tamper or Fault report from a wireless smoke detector

Seite 52

PC1404[348] Test Transmission Reporting CodesWalk Test Begin/EndThese reporting codes are sent when the walk test is initiated and terminated. These

Seite 53

5.3 Programming Descriptions[378] Test Transmission Time of DayThe panel can be configured to communicate a test transmission signal to the monitori

Seite 54

PC1404[381] Second Communicator Options[382] Third Communicator OptionsOption Description[1] RingbackON: Opening After Alarm Keypad Ringback Enabled

Seite 55

5.3 Programming Descriptions[383] Fourth Communicator Options[401] Downloading Option Codes[7] Residential DialON: Number of Dialing Attempts is 1 f

Seite 56 - [377] Communicator Variables

vPC1404 Wiring Diagram200–350 mA931404-112-WIRE AND 4-WIRE SMOKE DETECTORSFor NA installations only1.2, 4, 7 AhLCD5511LED5511PC1555RKZPK5500/PK5501PK5

Seite 57

PC1404[402] DLS Downloading Computer’s Telephone NumberThis is a 32-digit hexadecimal programming section. The downloading computer telephone number

Seite 58

5.3 Programming Descriptions[551-564] Extended PGM Attributes for PGM Type 29, Zone Follower [551]-[564]The following attributes are available for t

Seite 59 - Option Description

PC1404[700] Automatic Clock AdjustThe value entered here adds or subtracts seconds at the end of each day to compensate for inaccuracies in the syst

Seite 60 - Access Code Options

5.3 Programming Descriptions[703] Delay Between Dialing AttemptsFor standard (force) dialing, the panel will go off-hook, search for dial tone for 5

Seite 61 - [605] Opening by Master Code

PC1404[903] View Module Supervision In this mode, the system displays all of the modules presently enrolled on the system as indicated by the corres

Seite 62 - [700] Automatic Clock Adjust

6 Testing & Troubleshooting6 Testing & TroubleshootingTesting:• Power up system• Program options as required (see Section 5 Programming Work

Seite 63 - [900] Panel Version

PC1404PC520X Aux Power Supply Trouble • Ensure that a the power supply aux power terminal is not shorted to ground. • Ensure that the maximum power

Seite 64

6 Testing & TroubleshootingTrouble [5] Zone Fault Press [5] to determine specific zones with a Fault troubleOpen circuit is present on

Seite 65 - Trouble Summary:

PC1404 Appendix A: Reporting Code FormatsThe following tables contain Contact ID and Automatic SIA format reporting codes. See Programming Sections

Seite 66 - Trouble [2] AC Failure

Appendix A: Reporting Code Formats[345]-[346] Bell Circuit Trouble/Rest. Software deactivates the bell output if a short is detectedso no additiona

Seite 67 - Trouble [7] Not Used

1 Introduction11 IntroductionThis manual provides installation and programming informationfor the PC1404 four-zone panel security system. 1.1 Compatib

Seite 68 - &RQWDFW,'

PC1404 Table 3: Automatic Zone Alarm/Restoral Codes=RQH'HILQLWLRQ 6,$$XWR5HS&RGHV&RQWDFW,'$XWR5HS&RGHV&RQWDFW,&apo

Seite 69 - 2-wire Smoke Trouble/Rest

Appendix B: Communicator Format OptionsAppendix B: Communicator Format OptionsThe following format options are programmable in Section [350] Communi

Seite 70

PC1404 06Residential DialIf Residential Dial is programmed and an event that is programmed to communicate occurs, the panel will seize the line and

Seite 71 - DTMF Contact ID

Appendix C: Regulatory Approvals InformationAppendix C: Regulatory Approvals InformationNorth America FCC COMPLIANCE STATEMENTwill provide advance n

Seite 74

EuropeThis product is in conformity with:EMC Directive 2004/108/EC based on results using harmonized standards in accordance with article 10(5), R&

Seite 75

PC14042Zone Configuration• 31 zone types and 11 programmable zone attributes• Supports up to 4 hardwired NC, SEOL, DEOL zones, expandable to 8 with th

Seite 76

2 Installation2 InstallationThe following sections provide a thorough description of how towire and configure devices and zones.2.1 Installation Step