P R O G R A M D E S C R I P T I O N S
29
The panel will immediately go on line and begin the download process unless the Call Back option is enabled. If enabled,
the panel and computer will both hang up. The panel will then call the Download Computer Telephone Number and
wait for the computer to answer. Once the computer answers downloading will begin.
If the User Enabled DLS Window option is ON, the user can activate the downloading feature for a set period of
time by entering [
✱] [6] [Master Code] [5].
If the Full 6-hour User Enabled DLS Window option is enabled, when the user opens the DLS window with
[✱][6][Master code][5], the DLS window will remain open for six hours. The DLS window will remain open after a
successful hang-up from a downloading call. If the One Time 1-hour User Enabled DLS Window option is
enabled, when the user opens the DLS window with [✱][6][Master code][5], the DLS window will stay open for
one hour, and will close after a successful hang-up from a downloading call.
After six hours upon power up, the panel will not answer incoming calls unless the Answering Machine/Double
Call option is enabled, or the Number of Rings is programmed to be more than [0].
If the User Initiated Call-Up option is enabled, the user can have the panel initiate a call to the downloading
computer by pressing [✱][6][Master Code][6].
The Download Access Code
and Panel Identifier Code
are for security and proper identification. Both the panel
and the computer file should have the same information programmed before attempting to download.
The time to complete a successful download can be significantly reduced with the use of the PC-Link. This adaptor
makes it possible to perform on-site downloading. To Initiate Local Downloading via the PC-Link, enter [
✱] [8]
[Installer’s Code] [499] [Installer’s Code] [499]. All keypads will be busy for the duration of the PC-Link connection. The
status LEDs will display the current system status on the keypad where the PC-Link was initiated. For more information
on connecting the PC-Link, refer to your “PC-Link Download Kit Instruction Sheet”.
Downloading can also be performed through the LINKS1000 cellular communicator if the phone line is
disconnected. If using the LINKS1000 with Call Back, you need to program the LINKS1000 Preamble with the
downloading phone number in order for the panel to call the computer correctly.
When downloading labels for LCD keypads, only the LCD keypad assigned to slot 8 will receive the labels.
For more information refer to the Download Manual included with the computer software.
Answering Machine/ Double Call ........................... Section [401], Option [1]
User Enable DLS Window ..................................... Section [401], Option [2]
Call Back ................................................................. Section [401], Option [3]
User Initiated Call-up .............................................. Section [401], Option [4]
Answering Machine Double Call Timer ................. Section [405]
Download Computer Telephone Number .............. Section [402]
Download Access Code ........................................ Section [403]
Panel Identifier ........................................................ Section [404]
LINKS1000 Preamble (Downloading) ................... Section [490]
5.9 Partitions / Zone Assignment
A partition is a defined area which will operate independent of another area of the system. The panel can be
divided into two partitions. For example, in an office/warehouse installation it may be necessary to limit
warehouse employees from accessing the office and office employees from accessing the warehouse.
Any zone can be assigned to either, or both partitions. Any Access Code can be assigned to work on either, or
both partitions
(See Section 3.4 “[
✱
] Commands, [
✱
][5] Programming Access Codes”).
Global Zones
are zones assigned to both partitions. A common zone will only be armed when both partitions
are armed and will be disarmed when either partition is disarmed.
Keypads can be assigned to work on either partition or can be assigned for Global operation
(See Section 2.6
“Keypad Assignment”).
Each partition can be programmed to report using a different Account Number
(See Section 5.5 “Communicator
- Account Numbers”).
Some of the Programmable Output options are also selectable by Partition
(See Section 5.10 “PGM Outputs”).
The Partition 2 Enable option must be programmed before Partition 2 will operate.
At default zones 1 through 8 are assigned to Partition 1. If additional zones are being used or the application
requires two Partitions zones must be enabled to operate on the correct Partition.
Zones programmed as Null must be removed from both Partitions (See Section 5.1 “Zone Definition).
Partition 2 is Enabled .............................................. Section [201], Option [1]
Partition 1 Zone Assignments ............................... Section [202] to [205]
Partition 2 Zone Assignments ............................... Section [206] to [209]
5.10 PGM Outputs
There are 3 different types of Programmable Outputs available. They are listed as follows:
• PGM1 and PGM2 on the main board