PC5400DV - DVACS Interface Module
832
Wireless Expansion
832
Hardwired Expansion
PC5108 - 8 Zone Expansion Module
adds 8 hardwired general purpose burglary or fire zones
provides 100mA @ 12VDC auxiliary current, PTC protected
connect up to 1000' (305m) from control panel via KEYBUS
module current draw : 35mA @ 12VDC
PC5700 Fire Zone Expansion Module
a zone expansion module which provides :
- dual supervised telephone lines
- 2 Class A supervisory waterflow zones
- ground fault detection zone
- 4 general purpose fire or burglary zones
tamper and trouble reporting codes
connect up to 1000' (305m) from control panel via KEYBUS
module current draw : 150mA @ 12VDC
PC5720 Fire/Printer/DVACS Module
a zone expansion module which can also be used to provide
either a serial printer or DVACS communications interface
8 zone inputs include :
- 2 Class A supervisory waterflow zones
- ground fault detection zone
- 5 general purpose fire or burglary zones
as RS232 printer interface :
- baud rates… 300, 1200, 2400, 4800
- connect printer up to 200' (61m) from the PC5720 module
as DVACS interface :
- provides ULC Level 3 Line Security.
- provides full DVACS reporting of all system events.
- module is pre-programmed to SIA zone definitions
- events simultaneously communicated via DVACS and other
installed communications mode such as digital or cellular
- full cross supervision between the system control panel
and the DVACS module i.e… problems with one will be
communicated to the central station by the other.
PC5132 Wireless Receiver
add up to 32 DSC wireless detectors* including :
- WLS904 ........ passive infrared detector
- WLS906 ........ photoelectric smoke detector
- WLS907 ........ slim-line transmitter
* devices use standard Eveready Energizer
®
alkaline batteries
900 MHz true ‘Spread Spectrum’ technology, fully
supervised for communication integrity
easy sensor enroll process
supervisory transmissions every 12 minutes
programmable 1-24hr supervisory window
connect up to 1000' (305m) from control panel
via KEYBUS
module current draw : 130mA @ 12VDC
Wireless Control Devices
WLS908 Wireless Panic Pendant
- communicates a non-medical alarm to central station
- 32 pendants maximum…each occupying 1 alarm zone
- sealed non-replaceable battery
WLS909 Wireless Key
- remote arm/disarm control
- up to 16 keys per system
- 3 photo/electronic 1.5V batteries included
WLS910 Wireless Hand-Held Keypad
- personal remote keypad
- up to 4 wireless keypads per system (in addition to
hardwired keypads)
- 3 'AAA' batteries included
- central station requires Sur-Gard receiver with DVL2A
version 2 or higher software.
- complete with 8 pin jack, and communications and power
cables for connection to F1/F2 subset.
connect up to 1000' (305m) from control panel via KEYBUS
module current draw @ 12VDC : 80mA standby, 100mA
with printer, 120mA with DVACS
…Canada only
…Canada only
both PC5400 and PC5400DV may be used at the same time
on a system
provides ULC Level 3 Line Security.
provides full DVACS reporting of all system events.
module is pre-programmed to SIA zone definitions
events simultaneously communicated via DVACS and other
installed communications mode such as digital or cellular
full cross supervision between the system control panel
and the DVACS module e.g… problems with one will be
communicated to the central station by the other.
central station requires Sur-Gard receiver with DVL2A
version 2 or higher software.
complete with 8 pin jack, and communications and power
cables for connection to F1/F2 subset.
connect up to 1000' (305m) from control panel via KEYBUS
module current draw : 65mA @ 12VDC