PC5400DV - DVACS Interface Module
832
Wireless Expansion
832
Hardwired Expansion
PC5108 - 8 Zone Expansion Module
• adds 8 hardwired general purpose burglary or fire zones
• provides 100mA @ 12VDC auxiliary current, PTC protected
• connect up to 1000' (305m) from control panel via KEYBUS
• module current draw : 35mA @ 12VDC
PC5700 Fire Zone Expansion Module
• a zone expansion module which provides :
- dual supervised telephone lines
- 2 Class A supervisory waterflow zones
- ground fault detection zone
- 4 general purpose fire or burglary zones
• tamper and trouble reporting codes
• connect up to 1000' (305m) from control panel via KEYBUS
• module current draw : 150mA @ 12VDC
PC5720 Fire/Printer/DVACS Module
• a zone expansion module which can also be used to provide
either a serial printer or DVACS communications interface
• 8 zone inputs include :
- 2 Class A supervisory waterflow zones
- ground fault detection zone
- 5 general purpose fire or burglary zones
• as RS232 printer interface :
- baud rates… 300, 1200, 2400, 4800
- connect printer up to 200' (61m) from the PC5720 module
• as DVACS interface :
- provides ULC Level 3 Line Security.
- provides full DVACS reporting of all system events.
- module is pre-programmed to SIA zone definitions
- events simultaneously communicated via DVACS and other
installed communications mode such as digital or cellular
- full cross supervision between the system control panel
and the DVACS module i.e… problems with one will be
communicated to the central station by the other.
PC5132 Wireless Receiver
• add up to 32 DSC wireless detectors* including :
- WLS904 ........ passive infrared detector
- WLS906 ........ photoelectric smoke detector
- WLS907 ........ slim-line transmitter
* devices use standard Eveready Energizer
®
alkaline batteries
• 900 MHz true ‘Spread Spectrum’ technology, fully
supervised for communication integrity
• easy sensor enroll process
• supervisory transmissions every 12 minutes
• programmable 1-24hr supervisory window
• connect up to 1000' (305m) from control panel
via KEYBUS
• module current draw : 130mA @ 12VDC
Wireless Control Devices
WLS908 Wireless Panic Pendant
- communicates a non-medical alarm to central station
- 32 pendants maximum…each occupying 1 alarm zone
- sealed non-replaceable battery
WLS909 Wireless Key
- remote arm/disarm control
- up to 16 keys per system
- 3 photo/electronic 1.5V batteries included
WLS910 Wireless Hand-Held Keypad
- personal remote keypad
- up to 4 wireless keypads per system (in addition to
hardwired keypads)
- 3 'AAA' batteries included
- central station requires Sur-Gard receiver with DVL2A
version 2 or higher software.
- complete with 8 pin jack, and communications and power
cables for connection to F1/F2 subset.
• connect up to 1000' (305m) from control panel via KEYBUS
• module current draw @ 12VDC : 80mA standby, 100mA
with printer, 120mA with DVACS
…Canada only
…Canada only
• both PC5400 and PC5400DV may be used at the same time
on a system
• provides ULC Level 3 Line Security.
• provides full DVACS reporting of all system events.
• module is pre-programmed to SIA zone definitions
• events simultaneously communicated via DVACS and other
installed communications mode such as digital or cellular
• full cross supervision between the system control panel
and the DVACS module e.g… problems with one will be
communicated to the central station by the other.
• central station requires Sur-Gard receiver with DVL2A
version 2 or higher software.
• complete with 8 pin jack, and communications and power
cables for connection to F1/F2 subset.
• connect up to 1000' (305m) from control panel via KEYBUS
• module current draw : 65mA @ 12VDC