2
Digital Communicator Specifications:
Supports all major formats including SIA, Contact ID, and Res-
idential Dial
Split reporting of selected transmissions to each telephone
number
3 programmable telephone numbers
1 system account number, plus 8 partition account numbers
Supports LINKS1000 cellular communication
DTMF and pulse dialing
DPDT line seizure
Anti-jam detection
Event-initiated personal paging
System Supervision Features
The PC5020 continuously monitors a number of possible trouble
conditions including:
AC Power Failure
Trouble by Zone
Fire Trouble
Telephone Line Trouble
Low Battery Condition
Bell Output Trouble
Loss of Internal Clock
AUX Power Supply Fault
Tamper by Zone
Failure to Communicate
Module Fault (Supervisory or Tamper)
Camera Troubles via DLM-4L
False Alarm Prevention Features
Audible Exit Delay
Audible Exit Fault
Urgency on Entry Delay
Quick Exit
Swinger Shutdown
Recent Closing Transmission
Cross Zone Alarm
Burglary-verified timer
Double Hit Timer
Communication Delay
Rotating Keypress Buffer
Additional Features
Automatic arming by partition at a specified time, each day of
the week
Keypad activated alarm output and communicator test
Keypad lockout
Audio capability using the PC5928 Audio Interface Module,
which allows local intercom and central station 2-way listen-
in
All modules connect to the system via a four wire Keybus, up
to 1000’/305m from the main panel
Event buffer can be printed using PC5400 RS232 Serial Inter-
face module
Supports the Escort5580 Voice Prompt Module, with automa-
tion and lighting control
256 event buffer, time and date stamped
Uploading/downloading capability
Daylight savings time option
Downlook support (DLM-4L v1.0 and PC5108L)
1.4 Additional Devices
In addition to the information below, see the back cover for a
DSC Module Compatibility table.
Keypads
A maximum of 8 keypads can be connected to the control panel.
You can connect any combination of the following listed. Differ-
ent keypads (with function keys) can be used for different size
systems: 8 zone, 16 zone, 32 zone, and 64 zone.
PC5508Z: 8 zone LED keypad, with one zone input
PC5532Z: 32 zone LED keypad, with one zone input
PC5516Z: 16 zone LED keypad, with one zone input
LCD5500Z: LCD keypad, with one zone input
LCD5501Z: LCD-style keypad, with one zone input
NOTE:
The following keypad versions can only be used on
the first two partitions (Partition 1 and Partition 2), and the
first 8, 16, or 32 zones:
PC5508(Z), PC5516(Z), PC5532(Z) versions v2.00 and lower
LCD5500(Z) versions 2.x and lower
LCD5501Z versions 1.x and lower
PC5100 2-Wire Addressable Device Interface Module
The PC5100 module is used to connect 2-wire addressable
devices to the system. Up to 32 2-wire addressable devices can
be added to the system
NOTE:
PC5100 v1.0 and lower modules can only support
the first 32 zones on the Power864 system.
PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number
of zones on the system. Up to 7 modules can be connected to
increase the system zones to a maximum of 64. (See the PC5108
Installation Instructions Sheet.)
NOTE:
PC5108 v1.0 and lower modules can only support
the first 32 zones on the Power864 system. PC5108 v1.0 and
lower modules enroll as two modules and use up two
supervisory slots.
NOTE:
Do not mix PC5108 v1.x and lower modules with
PC5108 v2.0 and higher modules on the same system.
PC5132 Wireless Receiver Module
The PC5132 Wireless Receiver module can be used to connect up
to 32 wireless devices. All devices are fully supervised and use
standard ‘AAA’ or ‘AA’ alkaline batteries. (See the PC5132 Instal-
lation Manual for details.)
NOTE:
Only the first 32 zones on the Power864 system can
be used as wireless zones.
Additional wireless devices are available:
WLS904 Wireless Motion Detector
The Wireless Motion Detector can be used in conjunction with
the PC5132 Wireless Receiver to include wireless space protec-
tion. The unit comes with four ‘AAA’ batteries.
WLS906 Wireless Smoke Detector
The Wireless Smoke Detector can be used in conjunction with
the PC5132 Wireless Receiver to include wireless smoke detec-
tion. The unit comes with six ‘AA’ batteries.