TEMPERATURE SENSORS
CONVENTIONAL FIRE CONTROL PANELS
Conventional fire control panels from Bentel are designed and manufactured according to EN54 standards. The
microprocessor-based system is suited to small and medium applications. Each detection zone is equipped with an alarm
repeat output for selective alarm management in the event of fire.
BENTEL J408-2 / J408-4 / J408-8
2 / 4 / 8 Zone Conventional Fire Control Panel
Conforms with EN54•
Up to 21 devices can be connected to each zone: conventional fire detectors, •
alarm buttons, gas detectors
Gas zone compatible with 4-20 mA gas detectors •
One alarm-repeat output (open collector) for each input zone •
Manual call point recognition •
Signals missing detectors •
2 supervised, silenceable, bypassable 24 V alarm output for the activation of •
piezoelectric sirens, fire bells and flashers
Silenceable fault warning output for the activation of signalling and auxiliary •
devices
Supervised fire output for the telephone dialler activation •
Dry contact alarm-relay for the activation of auxiliary devices •
Day/Night mode•
Alarm verification time•
Programmable restorable and reset times•
Programmable from PC or keypad •
50 event log viewed via PC •
Alarm/fault memory activated until next reset •
Command for silencing sirens•
Keypad commands require key or pin code•
Ordering no. 76BJ408-2/4/8•
BENTEL J424-8
Expandable Fire Control Panel
Conforms with EN24•
Up to 21 devices can be connected to each zone conventional fire detectors, •
alarms buttons, gas detectors
Gas zone compatible with 4 – 20 mA gas detectors •
One alarm - repeat output (open collector) for each input zone •
Manual call point recognition •
Signals missing detectors •
2 supervised, silenceable, bypassable 24 V alarm output for the activation of •
the piezoelectric sirens, fire bells and flashers
Silenceable fault warning output for the activation of signalling and auxiliary •
devices
Supervised fire output for the telephone dialler activation •
Programmable open-collector output •
Dry contact alarm-relay for the activation of auxiliary devices •
Day/Night mode•
Alarm verification time•
Programmable restorable and reset times•
Programmable from PC or keypad•
50 event log view via PC•
Alarm/fault memory activated until next reset •
Command for silencing sirens •
Keypad commands require key pin code •
Ordering no. 76BJ424-8•