There are 2 formats in the PC6010 for communicating with the central station: SIA and Contact ID. The
system must be programmed to use the same communications format as the receiver at the central
station. Each format can be programmed to use automatically generated reporting codes. Please see the
“Communicator Toggles” section. The default format is SIA.
NOTE: When using the Contact ID format, only the first four digits of the account code will be
used. When using this format make sure to program the last two digits of the account code as
“FF”.
SIA 1986 Format
The system ID codes and the customer ID codes must be six decimal digits in length. The reporting codes must be 2 digits.
NOTE: Do not program the keypad lockout reporting code or the printer buffer nearly full reporting code.
The SIA format will transmit a 6 digit account code, a 2 digit identifier code and a 2 digit reporting code. The 2 digit identifier is
preprogrammed by the PC6010. The 2 digit reporting code is programmed by the installer with any hex number from 01 to FE.
You can also program the system to automatically generate SIA reporting codes (see the Communicator Toggles section).
Please see Appendix B Reporting Codes, for a list of SIA reporting codes.
Contact ID
The System ID code and Customer ID codes must be 4 decimal digits. The reporting codes must be 2 digits. Substitute the HEX
digit “A” for the zero (0). To prevent the panel from reporting an event, the reporting code should be programmed as [00] or [FF].
NOTE: Do not program the Opening After Alarm, Buffer Nearly Full, Installer Lead In and Installer Lead Out reporting
codes.
Zone Alarms and Restorals can be programmed to send different messages to the monitoring station. For example, if the
Reporting code for zone 5 is programmed with ‘34’, the monitoring station will receive the message ‘*BURG*
- ENTRY/EXIT - 5’,
where 5 is the number of the zone which has been activated. Please see Appendix B Reporting Codes, for a list of Contact ID
reporting codes.
You can also program the system to automatically generate Contact ID reporting codes (see the Communicator Toggles section).