Unlock Door on Request To Exit?
YES = A Request To Exit will cause the door to unlock for the programmed Door Unlock Time. The LED
output will activate to indicate to the user that the door can be opened.
NO = A Request To Exit will not cause the door to unlock. If the door is opened within the door unlock
time the door will not generate a Door Forced Open Event.
Default condition is YES.
Flash the reader LED when armed?
YES = Enabling this feature will indicate the armed status of the assigned area(s) to be enunciated on the
LED of the card reader and the LED output to flash when all areas that the ARM/DISARM MASK is
assigned to are armed. The LED will flash slowly for the duration of the armed period of the
selected areas.
NOTE: The area(s) that the zone is assigned to must also be assigned to the Arm/Disarm Mask for
proper operation of this function.
NO = The LED of the access card reader and the LED output will not indicate the armed status.
Default condition is YES.
Relock On Request To Arm?
YES = A Request To Arm will relock the door when the arm input is activated.
NO = A Request to Arm will not relock the door.
Default condition is NO.
Both readers on one door?
YES = Enabling this option will assign both readers of the PC6820 to the same door input. This will
allow the PC6820 to control access in and out of a secured area. The zone assignment of both
door must be assigned to the same zone and areas on the PC6010. Any time an access card is
used to open the door the other door will also allow access to prevent door forced open event
(both lock outputs will unlock). Each door can be programmed to have its own access levels
(allowing the ability to control entry and exit permissions for any door on the system), and
schedules. NOTE: Only enable this option on door one.
NO = Each reader will be assigned to a separate door input designated Door 1 and Door 2.
Default condition is NO.
User code required to gain access?
YES = When this option is enabled the PC6820 will not allow access to the door, or to the keypad, until
the user enters an access code. When a user passes their access card, the LED on the reader will
flash twice every second to indicate to the user that the reader is waiting for a code to be entered.
The user then has 15 seconds to enter their code. If the access code is entered successfully, then
the reader will grant access. The access code entered must match the code for the user card.
Access will not be granted if the access code does not match the code for the access card, even if
the code is valid on the system.
When access is denied to the user due to a wrong/invalid code being entered, or if time has
expired waiting for the access code, the LED on the reader will flash 3 times every second and the
buzzer will give an audible beep 3 times every second. If an error is made when entering the
access code, the user can press the [#] key and re-enter their access code.
NOTE: A reader that requires a code will follow the Total Bad Codes and Lockout Duration programmed
in the Keypad Lockout Options section.
NO = No access code is required. Default condition is NO.
NOTE: Only use this feature if you have installed either readers with built-in keypads, or where you
have installed PC6501 keypads near each reader. If you have installed keypads near the readers, you
should also assign them to the readers in the Keypad/Reader Assignment section. When you assign a
reader to a keypad, you should not set up the reader to also control a door. The reader should only be
used to grant access to the keypad.
LED output Reversed?
YES = Will make the normal state of the LED output of the PC6820 energized.
NO = The normal state of the LED output will be de-energized.
Default condition is NO.
Lock door when the zone input is closed?
YES = When the door is unlocked by an access card or by a REX device the door will relock once the zone
is opened and then closed.
NO = When the door is unlocked by an access card or by a REX device the door will relock once the zone
is opened.
Default condition is NO.
FLASH WHEN ARM?FLASH WHEN ARM?
FLASH WHEN ARM?FLASH WHEN ARM?
FLASH WHEN ARM?
YY
YY
Y
RELOCK ON ARM?RELOCK ON ARM?
RELOCK ON ARM?RELOCK ON ARM?
RELOCK ON ARM?
NN
NN
N
LOCK ON CLOSE?LOCK ON CLOSE?
LOCK ON CLOSE?LOCK ON CLOSE?
LOCK ON CLOSE?
NN
NN
N
LED REVERSED?LED REVERSED?
LED REVERSED?LED REVERSED?
LED REVERSED?
NN
NN
N
TWO READERS?TWO READERS?
TWO READERS?TWO READERS?
TWO READERS?
NN
NN
N
SYSTEM AREASYSTEM AREA
SYSTEM AREASYSTEM AREA
SYSTEM AREA
6820 OPTIONS6820 OPTIONS
6820 OPTIONS6820 OPTIONS
6820 OPTIONS
CODE REQUIREDCODE REQUIRED
CODE REQUIREDCODE REQUIRED
CODE REQUIRED
NN
NN
N
UNLOCK ON REX?UNLOCK ON REX?
UNLOCK ON REX?UNLOCK ON REX?
UNLOCK ON REX?
YY
YY
Y