Keypad Lockout Options
This section contains programming for the keypad and reader lockout features. After a programmed
number of incorrect attempts to enter an access or installer’s code, the keypad will lock users out.
This prevents users from performing any system function. A message “Keypad Lockout is Active” will
be displayed for the lockout duration. Keypad lockout is automatically enabled on all system
keypads. See “READER LOCKOUT” under “System Options” to enable the keypad lockout feature
on PC6820 readers.
Enter the number of incorrect code entries (from 000 to 255) required to activate keypad lockout.
The default setting is 005.
This section determines the number of minutes the keypad lockout will be active. Enter the duration
of the keypad lockout. Valid entries are from 000 to 255. The default setting is 015.
System Times
These times apply to the whole system.
Program the amount of time (from 000 to 255 minutes) the bell output will activate for when an
alarm occurs. The factory default setting is 004 (4 minutes). Bell Cutoff is for any output (Bell, SW
Aux or PGM) that is programmed for Fire and Burg, Inv Fire and Burg, Burg Only, Inv Burg Only, Fire
Only, Inv Fire Only, and Tamper.
Program the amount of time (from 000-255 seconds) that a TLM Trouble will be delayed before it is
annunciated on the trouble group. The default is 060.
Program the amount of time (000-255 minutes) before an AC Trouble will be annunciated on the
trouble group. The default is 060.
Program the time (000-255 minutes) before the keypad will display an AC trouble in the fault list.
This will delay the “Trouble Group” annunciation and the “AC Fail TX Delay”. This delay does not
apply to the keypad Power light. If there is an AC trouble, the Power light on the keypad will turn off
immediately. The default is 000 minutes.
Program the time (000-255 minutes) before a “Combus Low PWR” trouble will occur. The default is
000 minutes.
Program the time (000-255 minutes) before a TLM trouble will be logged and displayed in the fault
list. The default is 000 minutes.
Program the amount of time (000 - 255 Minutes) before a Police Code Alarm reporting code will be
sent to the central station. A Police Code Alarm is sent when 2 zone alarms occur within the
programmed time. Default is 060 minutes.
Program the time in minutes that automatic arming can be delayed. Users can delay automatic
arming on assigned areas from a system keypad, or an PC6820 reader with a POST input. When the
programmed delay time expires, automatic arming will begin again. Users may delay automatic
arming as many times as desired. To delay automatic arming at a system keypad, users must enter
their access code, and then follow the available choices displayed on the keypad. To delay automatic
arming at an PC6820 reader, users must first pass an access card through the reader, and then
activate the POST input. The default delay is 030 minutes.
KYPD LOCKOUT OPTKYPD LOCKOUT OPT
KYPD LOCKOUT OPTKYPD LOCKOUT OPT
KYPD LOCKOUT OPT
(1)(1)
(1)(1)
(1)
TOTAL BAD CODESTOTAL BAD CODES
TOTAL BAD CODESTOTAL BAD CODES
TOTAL BAD CODES
(0)(0)
(0)(0)
(0)
LOCKOUT DURATIONLOCKOUT DURATION
LOCKOUT DURATIONLOCKOUT DURATION
LOCKOUT DURATION
(1)(1)
(1)(1)
(1)
SYSTEM TIMESSYSTEM TIMES
SYSTEM TIMESSYSTEM TIMES
SYSTEM TIMES
(2)(2)
(2)(2)
(2)
BELL CUTOFFBELL CUTOFF
BELL CUTOFFBELL CUTOFF
BELL CUTOFF
(00)(00)
(00)(00)
(00)
TLM DELAYTLM DELAY
TLM DELAYTLM DELAY
TLM DELAY
(01)(01)
(01)(01)
(01)
AC FAIL DELAYAC FAIL DELAY
AC FAIL DELAYAC FAIL DELAY
AC FAIL DELAY
(02)(02)
(02)(02)
(02)
AC DELAYAC DELAY
AC DELAYAC DELAY
AC DELAY
(03)(03)
(03)(03)
(03)
LOW COMBUS DELAYLOW COMBUS DELAY
LOW COMBUS DELAYLOW COMBUS DELAY
LOW COMBUS DELAY
(04)(04)
(04)(04)
(04)
TLM TROUB. DELAYTLM TROUB. DELAY
TLM TROUB. DELAYTLM TROUB. DELAY
TLM TROUB. DELAY
(05)(05)
(05)(05)
(05)
POLICE CODE TIMEPOLICE CODE TIME
POLICE CODE TIMEPOLICE CODE TIME
POLICE CODE TIME
(06)(06)
(06)(06)
(06)
DELAY AUTOARMDELAY AUTOARM
DELAY AUTOARMDELAY AUTOARM
DELAY AUTOARM
(07)(07)
(07)(07)
(07)
Kommentare zu diesen Handbüchern