6. User Call-Up - If enabled by the Installer, the panel will make 1 attempt to call the downloading computer. The
downloading computer must be waiting for the panel to call before downloading can be performed.
7. Music Input On/Off - If enabled on the PC5936 Audio Interface Module, the user can turn Background Music on
or off.
8. User Walk Test (For Europe only) - This test allows the user to verify operation of system detectors and notifies
the central station that a Walk Test is in progress.
Note: Fire zones, the [F] key, and 2-wire Smoke detectors are excluded from this test. Violation of these zones will cause
the system to exit the walk test then generate and transmit alarm condition to the central station.
1. Press [*][6][8] to enable Walk Test. The system will notify the Central Station that a walk test has begun.
2. Violate all each detector (zone) in sequence. A squawk will occur at the keypad and the violation will be
recorded in the Event Buffer.
3. Restore zones. Press [*][6][8] to end the Walk Test. The system will notify the Central Station that the walk test
has been terminated.
Note: If a zone is not violated within 15 minutes of activating the Walk Test, the system will automatically exit the Walk
Test and resume normal operation.
System Testing
Testing Your System
Testing Your Keypad Sounder and Siren
The System Test provides several system tests, and a two-second check of the keypad sounder and bell or siren.
1. Press [*][6] [Master Code] [4].
2. The following will occur:
o The system activates all keypad sounders and bells or sirens for two seconds. All keypad lights turn ON.
o PK5500/LCD5500 keypads will light all pixels.
o The Ready, Armed, and Trouble LED’s will flash for the duration of the test.
3. To exit the function menu, press [#].
Testing Your Entire System
All smoke detectors in this installation must be tested by your smoke detector installer or dealer once a year to ensure
they are functioning correctly. It is the user’s responsibility to test the system weekly (excluding smoke detectors).
Ensure you follow all the steps in the ‘Testing Your System’ section above.
Note: Should the system fail to function properly, call your installation company for service immediately.
1. Prior to testing, ensure that the system is disarmed and the Ready light is on.
2. Press [#] and close all zones to return the system to the Ready state.
3. Perform a System Test by following the steps in the previous section.
4. To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion detector
areas).
PK5500/LCD5500 keypads will display the following message when each zone (detector) is activated: “Secure System
Before Arming < >”, “Secure System or Enter Code” or “Secure or Arm System”. Use the [< >] keys to view which zones
are open. The message will disappear when the zones are closed.