Activating All Bypassed Zones
To activate all bypassed zones:
1. Press [*][1], then your [access code] (if necessary).
2. Press [0][0].
3. To exit bypassing mode and return to the Ready state, press [#].
Recalling Bypassed Zones
To recall the last set of bypassed zones:
1. Press [*][1], then your [access code] (if necessary).
2. Press [9][9].
3. To exit bypassing mode and return to the Ready state, press [#].
Bypass Groups
A Bypass Group is a selection of zones programmed into the system. If you bypass a group of zones on a regular basis,
you can program them into the Bypass Group, so that you do not have to bypass each zone individually every time. One
Bypass Group can be programmed on each partition.
To program a Bypass Group:
1. Press [*][1], then your [access code] (if necessary).
2. Enter the two-digit numbers (01-64) of the zones to be included in the Bypass Group. On PK5500/LCD5500
keypads, you can also use the [< >] keys to find the zone to be included in the bypass group, and then press [*]
to select the zone.
3. To save the selected zone into the group, press [9][5].
4. To exit bypassing mode and return to the Ready state, press [#].
To select a Bypass Group when arming the system:
1. Press [1][*], then your [access code] (if necessary).
2. Press [9][1]. The next time the system is armed, the zones in this group will be bypassed.
3. To exit bypassing mode and return to the Ready state, press [#].
Note: Bypass Groups are only recalled if the system is armed/disarmed after programming the bypass group. This feature
is not to be used in UL Listed installations.
Door Chime (Entry/Exit Beeps)
To turn the door chime function on or off, press and hold the Chime key for 2 seconds or press [*][4].
Panic Alarms
Emergency Keys
Press the [F], [A] or [P] key for 2 seconds to generate a Fire, Auxiliary or Panic alarm. The keypad sounder will beep
indicating that the alarm input has been accepted and transmission to the central station is underway. Ask your alarm
company if the emergency keys are available on your system.