P R O G R A M D E S C R I P T I O N S
26
Please refer to Appendix A: “Reporting Codes”for a list of Contact ID Identifiers.
Contact ID Uses Programmed/Automatic Codes .. [381]: [7]
5.6.3 SIA (Level 2)
SIA is a specialized format that will communicate information quickly using frequency shift keying (FSK) rather than
pulses. The SIA format will automatically generate the type of signal being transmitted, such as Burglary, Fire,
Panic etc. The two digit reporting code is used to identify the zone or access code number.
SIA forSIA for
SIA forSIA for
SIA for
mat must be used if Downlook is rmat must be used if Downlook is r
mat must be used if Downlook is rmat must be used if Downlook is r
mat must be used if Downlook is r
equirequir
equirequir
equir
ed.ed.
ed.ed.
ed.
If the SIA format is selected the panel can be programmed to automatically generate all zone and access codes
numbers eliminating the need to program these items.
If the SIA Sends Automatic Reporting Codes option is enabled the panel will operate as follows:
1. If the reporting code for an event is programmed as [00] the panel will not attempt to call the central station.
2. If the reporting code for an event is programmed as anything from [01] to [FF] the panel will AUTOMATICALLY
generate the zone or access code number.
3. Bypassed zones will always be identified when partial closing the system.
The Communicator Call Direction Options can be used to disable reporting of events such as Openings/Closings.
Also, if all the Opening/Closing reporting codes were programmed as [00] the panel would not report.
If the SIA Sends Automatic Reporting Codes option is disabled the panel will operate as follows:
1. If the reporting code for an event is programmed as [00] or [FF] the panel will not attempt to call central station.
2. If the reporting code for an event is programmed as anything from [01] to [FE] the panel will send the
programmed reporting code.
3. Bypassed zones will not be identified when partial closing the system.
Do not prDo not pr
Do not prDo not pr
Do not pr
ogram the second phone number for the SIA rogram the second phone number for the SIA r
ogram the second phone number for the SIA rogram the second phone number for the SIA r
ogram the second phone number for the SIA r
eporepor
eporepor
epor
ting code forting code for
ting code forting code for
ting code for
mat (Section [360]) if themat (Section [360]) if the
mat (Section [360]) if themat (Section [360]) if the
mat (Section [360]) if the
Automatic ReporAutomatic Repor
Automatic ReporAutomatic Repor
Automatic Repor
ting Code option is enabled (Section [381]).ting Code option is enabled (Section [381]).
ting Code option is enabled (Section [381]).ting Code option is enabled (Section [381]).
ting Code option is enabled (Section [381]).
Communicator Format ............................................ Section [360]
SIA Sends Automatic Reporting Codes ................ Section [381], Option [3]
Communicator Call Direction Options ................... Section [361] to [368]
SIA Identifiers ......................................................... Appendix B
5.6.4 Residential Dial
If Residential Dial is programmed and an event that is programmed to communicate occurs, the panel will seize
the line and dial the appropriate phone number(s). Once the dialing is complete, the panel will emit an ID tone
and wait for a handshake (press a 1, 2, 4, 5, 7, 8, 0, ✱ or # key from any phone). It will wait for this handshake
for the duration of Post Dial Wait for Handshake timer.
Once the panel receives the handshake, it will emit an
alarm tone over the phone line for 20 seconds. If several alarms occur at the same time, only one call will be
made to each phone number the panel is programmed to call.
Communicator Format Options .............................. Section [360]
Communicator Call Direction Options ................... Section [361] to [368]
5.6.5 Pager Format
The Communicator Format option for either phone number can be programmed for Pager Format. If an event
occurs and the Communicator Call Direction options direct the call to a phone number with the Pager Format
selected the panel will attempt to page.
When calling a pager extra digits will be required to make it work properly.
The following is a list of Hex digits and what function they perform:
Hex [B] - simulates the [✱] key on a touch tone phone Hex [E] - two second pause
Hex [C] - simulates the [#] key on a touch tone phone Hex [F] - end of phone number marker
Hex [D] - forces the panel to search for dial tone
The panel will attempt to call the pager one time. After dialing the digits in the phone number the panel will send
the account number and reporting code followed by the [#] key (Hex [C]).
There is no ringback when using Pager Format. The panel has no way of confirming if the pager was called
successfully; a failure to communicate trouble will only be generated once the maximum number of attempts has
been reached.
The Pager ForThe Pager For
The Pager ForThe Pager For
The Pager For
mat cannot be used with the LINKS1000 cellular communicatormat cannot be used with the LINKS1000 cellular communicator
mat cannot be used with the LINKS1000 cellular communicatormat cannot be used with the LINKS1000 cellular communicator
mat cannot be used with the LINKS1000 cellular communicator
..
..
.
Do not use the digit C in a rDo not use the digit C in a r
Do not use the digit C in a rDo not use the digit C in a r
Do not use the digit C in a r
eporepor
eporepor
epor
ting code when using Pager Forting code when using Pager For
ting code when using Pager Forting code when using Pager For
ting code when using Pager For
mat. In most cases, the digit C will bemat. In most cases, the digit C will be
mat. In most cases, the digit C will bemat. In most cases, the digit C will be
mat. In most cases, the digit C will be
interprinterpr
interprinterpr
interpr
eted as a [#], which will tereted as a [#], which will ter
eted as a [#], which will tereted as a [#], which will ter
eted as a [#], which will ter
minate the page beforminate the page befor
minate the page beforminate the page befor
minate the page befor
e it has finished.e it has finished.
e it has finished.e it has finished.
e it has finished.
If the panel detects a busy signal, it will attempt to page again. It will make the maximum number ofIf the panel detects a busy signal, it will attempt to page again. It will make the maximum number of
If the panel detects a busy signal, it will attempt to page again. It will make the maximum number ofIf the panel detects a busy signal, it will attempt to page again. It will make the maximum number of
If the panel detects a busy signal, it will attempt to page again. It will make the maximum number of
attempts prattempts pr
attempts prattempts pr
attempts pr
ogrammed in section [160]. Forogrammed in section [160]. For
ogrammed in section [160]. Forogrammed in section [160]. For
ogrammed in section [160]. For
ce dialing should be disabled when using Pager force dialing should be disabled when using Pager for
ce dialing should be disabled when using Pager force dialing should be disabled when using Pager for
ce dialing should be disabled when using Pager for
mat.mat.
mat.mat.
mat.
When using Pager forWhen using Pager for
When using Pager forWhen using Pager for
When using Pager for
mat, you must prmat, you must pr
mat, you must prmat, you must pr
mat, you must pr
ogram two hex digit E’ogram two hex digit E’
ogram two hex digit E’ogram two hex digit E’
ogram two hex digit E’
s at the end of the phone numbers at the end of the phone number
s at the end of the phone numbers at the end of the phone number
s at the end of the phone number
..
..
.
Kommentare zu diesen Handbüchern