P R O G R A M D E S C R I P T I O N S
28
on the Bell Output of the main panel. The Bell Circuit Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
A Fire Trouble Alarm Reporting Code will be transmitted immediately when an open condition is measured on any
Fire type zone
(See Section 5.1 “Zone Definitions”).
The Fire Trouble Restoral Reporting Code will be transmitted as
soon as the problem is corrected.
The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is shorted.
The AUX output control incorporates a fuseless design. When excessive current is drawn the panel will
automatically shut off the output. The panel will constantly check the AUX output and when the excessive
current draw is removed the panel will reset the output and transmit an Auxiliary Power Supply Trouble
Restoral Reporting Code.
A TLM Trouble Reporting Code can only be transmitted if an Alternate Communicator is being used
(See
Section 5.26 “LINKS1000 Cellular Communicator”)
. The panel will only transmit the signal after the time
programmed for the TLM Trouble Delay. The TLM Restoral Reporting Code will be transmitted immediately
once the trouble is restored.
A General System Trouble Reporting Code will be transmitted if the panel detects any of the following on the
PC5204 Power Supply/Output Module: AC Power Failure, Low Battery, AUX Output Trouble, Output #1
Supervisory trouble. The General System Trouble Restoral Reporting Code will be transmitted when all of the
listed problems are corrected.
A General System Supervisory Trouble Reporting Code will be transmitted if any module goes missing from
the Keybus. If the module is a zone expander the panel will also transmit the Zone Expander Supervisory
Alarm Trouble Reporting Code. The panel will send a General System Supervisory Restoral Reporting Code
when the problem is corrected as well as a Zone Expander Supervisory Restoral Reporting Code if the
module is a zone expander.
5.7.6 Zone Restorals
If the Restoral on Bell Time-out option is selected, the panel will send the Zone Restoral Reporting Code for
the zone if the bell cut-off time has expired
and
the zone is secured. If the zone is not secured when the bell cut-
off time expires, the panel will send the restoral immediately once the zone is secured, or when the system is
disarmed. If the Restoral on Bell Time-out option is not selected, the panel will immediately send the Zone
Restoral Reporting Code when the zone is secured, regardless of whether or not the alarm output is active.
24 Hour type zones will r24 Hour type zones will r
24 Hour type zones will r24 Hour type zones will r
24 Hour type zones will r
eporepor
eporepor
epor
t the rt the r
t the rt the r
t the r
estoral immediately when the zone is securestoral immediately when the zone is secur
estoral immediately when the zone is securestoral immediately when the zone is secur
estoral immediately when the zone is secur
ed.ed.
ed.ed.
ed.
Restoral on Bell Time-out ....................................... Section [380], option [2]
AC Failure Communication Delay Time ................. Section [370]
5.8 Downloading
Downloading allows programming of the entire control panel via a computer, modem and telephone line. All
functions and features, changes and status, such as trouble conditions and open zones can be viewed or
programmed by downloading.
When power is applied to the panel, a 6 hour downloading window can be enabled. This will allow youWhen power is applied to the panel, a 6 hour downloading window can be enabled. This will allow you
When power is applied to the panel, a 6 hour downloading window can be enabled. This will allow youWhen power is applied to the panel, a 6 hour downloading window can be enabled. This will allow you
When power is applied to the panel, a 6 hour downloading window can be enabled. This will allow you
to perto per
to perto per
to per
forfor
forfor
for
m downloading without having to do any keypad prm downloading without having to do any keypad pr
m downloading without having to do any keypad prm downloading without having to do any keypad pr
m downloading without having to do any keypad pr
ogramming.ogramming.
ogramming.ogramming.
ogramming.
If the Answering Machine/ Double Call option is enabled (or during the first 6 hours after power up) the panel
will answer incoming calls for downloading provided the following conditions occur:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a timer.
3. If the panel hears another ring before the Answering Machine Double Call Timer
expires it will answer on
the first ring of the second call.
The panel will immediately go on line and begin the download process unless the Call Back option is enabled. If
enabled, the panel and computer will both hang up. The panel will then call the Download Computer Telephone
Number and wait for the computer to answer. Once the computer answers downloading will begin.
If the User Enabled DLS Window option is ON, the user can activate the downloading feature for a set period of
time by entering [
✱] [6] [Master Code] [5].
If the Full 6-hour User Enabled DLS Window option is enabled, when the user opens the DLS window with
[✱][6][Master code][5], the DLS window will remain open for six hours. The DLS window will remain open after a
successful hang-up from a downloading call. If the One Time 1-hour User Enabled DLS Window option is
enabled, when the user opens the DLS window with [✱][6][Master code][5], the DLS window will stay open for
one hour, and will close after a successful hang-up from a downloading call.
After six hours upon power up, the panel will not answer incoming calls unless the Answering Machine/Double
Call option is enabled, or the Number of Rings is programmed to be more than [0].
If the User Initiated Call-Up option is enabled, the user can have the panel initiate a call to the downloading
computer by pressing [✱][6][Master Code][6].
The Download Access Code
and Panel Identifier Code
are for security and proper identification. Both the panel
and the computer file should have the same information programmed before attempting to download.