S Y S T E M I N T R O D U C T I O N
2
False Alarm Prevention Features
Audible Exit Delay Audible Exit Fault Urgency on Entry Delay
Quick Exit Swinger Shutdown • Recent Closing Transmission
Cross Zone Alarm Burglary-verified timer Double Hit Timer
Communication Delay Rotating Keypress Buffer
Additional Features
Auto Arm by Partition at Specified Time each day of the week
Keypad Activated Alarm Output and Communicator Test
Keypad Lockout
Audio Capability using the PC5928 Audio Interface Module which allows local intercom and Central Station 2-
Way Listen in.
All modules connect to the system via a four wire Keybus up to 1000’/305m from main panel
Event Buffer can be printed using PC5400 RS232 Serial Interface module
Supports the Escort5580 Voice Prompt Module with Automation/Lighting Control
128 Event Buffer, Time and Date Stamped
Upload/Download Capability
Daylight Savings time option
Downlook support (DLM-4L: v1.0L and PC5108L)
1.2 Additional Devices
In addition to the information below, see the inside back cover for a DSC Module Compatability table.
1.2.1 Keypads
A maximum of eight (8) keypads can be connected to the control panel and can be any combination of the
following listed. Different keypads (with function keys) can be used for different size systems; 8 zone, 16 zone
and 32 zone.
TM
Ready Armed Trouble
AM
PC5508Z / KP5508Z PC5516Z/KP5516Z PC5532Z/KP5532Z LCD5500Z/KPL5500Z LCD5501Z/KP5501Z
8 zone LED keypad 16 zone LED keypad 32 zone LED keypad Programmable Message Fixed Message LCD
LCD keypad
1.2.2 PC5108 Eight Zone Expander Module
Eight zone expander module can be used to increase the number of zones on the
system. Up to 3 modules can be connected to increase the system zones to a
maximum of 32.
(See PC5108 Installation Instructions Sheet.)
1.2.3 PC5132 Wireless Receiver Module
The PC5132 Wireless Receiver module can be used to connect up to 32 wireless
devices. All devices are 433 MHz, fully supervised
(see PC5132 Installation Manual
for details).
Additional wireless devices are available:
WLS904PL Wireless Motion Detector
The wireless Motion Detector can be used in conjunction with the PC5132 Wireless Receiver to include wireless
space protection.
WLS906 Wireless Smoke Detector
The wireless Smoke Detector can be used in conjunction with the PC5132 Wireless Receiver to include
wireless smoke detection. The unit comes with six ‘AA’ batteries
.
WLS925L Mini Door/Window Contact
The wireless Slimline Universal Transmitter can be used with the PC5132 Wireless Receiver to add wireless door
or window contacts in a smaller package.
WLS919 Wireless Key
The Wireless Key can be used in conjunction with the PC5132 Wireless Receiver to include a simple and mobile
method of arming and disarming the system. This system can have a maximum of 16 wireless keys.