Main PGM1 and PGM2 Outputs
The PGM outputs can be programmed to activate for any one of the 56 options listed in the PGM
outputs list. Normally the outputs energize when they are activated. The outputs will de-energize when
they are activated if any “INV” options are selected. The default output type is 25 (Holdup).
Program the output type from the list of 56 output options (see “Programmable Output Options’).
Depending on which output option you select, you may also need to program the area(s) the output will
be active on, the zone the output will follow, the date schedule the output will follow, and/or a pulse
timer for the output. The default output type is 25 (Holdup).
NOTE: Refer to “Programmable Output Options” for a list of the available options.
PC6204 Options
Each relay of any 4204 relay module can be programmed to activate for any one of the 56 options listed
in the PGM outputs list. Normally each relay will be de-energized, and energizes when it is activated. The
relay will normally be energized, and then de-energized when it is activated, if any “INV” option is
selected. Output 1 will always be active if left at the default of (15) Combus power, unless there is no
incoming Combus power.
Program the output type from the list of 56 output options (see “Programmable Output Options”).
Depending on which output option you select, you may also need to program the area(s) the output will
be active on, the zone the output will follow, the date schedule the output will follow, and/or a pulse
timer for the output.
NOTE: PC6202 #01 Output #1 is default a “Burg Only” (02) output. Do not use this output to
repower Combus without changing the output type to “Combus Power” (15).
PC6216 Options
A maximum of nine PC6216 output modules can be connected to the system.
First select the PC6216 to be programmed, then select the option it is going to be programmed for. The
PC6216 follow one of nine custom PGM output groups.
The custom group allows each of the 16 outputs to be individually programmed with one of the 56
options listed in the PGM outputs list. Each output is programmed in the “4216 CUSTOM” section.
PC6216 Custom
This section is for programming each of the 9 custom groups for different options. Program one option
for each of the 16 outputs. You can program each output for any of the 56 listed programmable output
options. You can assign each PC6216 modules to one of these groups (see “PC6216 Options”).
Depending on which output option you select, you may also need to program the area(s) the output will
be active on, the zone the output will follow, the date schedule the output will follow, and/or a pulse
timer for the output.
PGM OUTPUTSPGM OUTPUTS
PGM OUTPUTSPGM OUTPUTS
PGM OUTPUTS
(06)(06)
(06)(06)
(06)
MAIN PGM1 OUTMAIN PGM1 OUT
MAIN PGM1 OUTMAIN PGM1 OUT
MAIN PGM1 OUT
(0)(0)
(0)(0)
(0)
CUSTOM GROUPCUSTOM GROUP
CUSTOM GROUPCUSTOM GROUP
CUSTOM GROUP
(01) (01)
(01) (01)
(01)
(09) (09)
(09) (09)
(09)
6216 OPTIONS6216 OPTIONS
6216 OPTIONS6216 OPTIONS
6216 OPTIONS
(3)(3)
(3)(3)
(3)
6204 OPTIONS6204 OPTIONS
6204 OPTIONS6204 OPTIONS
6204 OPTIONS
(2)(2)
(2)(2)
(2)
PGM Outputs
MAIN PGM2 OUTMAIN PGM2 OUT
MAIN PGM2 OUTMAIN PGM2 OUT
MAIN PGM2 OUT
(1)(1)
(1)(1)
(1)
CUSTOM GROUPCUSTOM GROUP
CUSTOM GROUPCUSTOM GROUP
CUSTOM GROUP
(01) (01)
(01) (01)
(01)
(09) (09)
(09) (09)
(09)
6216 CUSTOM6216 CUSTOM
6216 CUSTOM6216 CUSTOM
6216 CUSTOM
(4)(4)
(4)(4)
(4)
Seitenansicht 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 51 52

Kommentare zu diesen Handbüchern

Keine Kommentare