Each zone can have its own unique label to help identify it on the LCD keypad. Upon first entering this
section, the LCD will display the current zone label.
NOTE: The maximum length of the zone label is 14 characters.
A cursor will appear under the first character of the label. Move the cursor to the left or right using the
[<][>] keys. Use the 1-9 number keys on the keypad to enter letters as follows:
[1] = A, B, C, 1 [2] = D, E, F, 2 [3] = G, H, I, 3 [4] = J, K, L, 4 [5] = M, N, O, 5
[6] = P, Q, R, 6 [7] = S, T, U, 7 [8] = V, W, X, 8 [9] = Y, Z, 9, 0 [0] = Space
For example, if you press the [4] key, the letter ‘J’ will appear above the cursor on the display. Press the [4]
key again, the letter ‘K’ will appear above the cursor. Press the [4] key a third time and the letter ‘L’ will
appear above the cursor. Press it again and the number ‘4’ will appear on the display. If a different key is
pressed, for example the [6] key, the cursor will automatically move to the right one space, and the letter
‘P’ will be displayed. To erase a character, move the cursor under the character using the [<][>] keys, and
press the [0] key.
While programming the zone label, press [*] to call up an options menu. To select an option, either press
the corresponding number key, or toggle through the options using the [<][>] keys, and press [*] to select.
[0] Clear Display [1] Clear to End [2] Change Case [3] ASCII Entry (See Appendix A)
[4] Save
[0] Clear Display will clear the entire zone label.
[1] Clear to End will clear the display from the character where the cursor was located to the end of the
display.
[2] Change Case will toggle the letter entry between upper case letters (ABC...) and lower case letters
(abc...).
[3] ASCII Entry is for entering uncommon characters. There are 255 characters, but 000 to 031 are not
used. Use the [<] [>] keys to toggle through the characters or enter a 3 digit number from 032 to 255.
Press the [*] key to enter the character into the zone label (see Appendix A for the ASCII characters chart).
[4] Save the label programmed and return to the previous menu.
Zone Type
Select the zone type for the selected zone. Upon entering this section, the current programmed zone type
is displayed.
For example, zone 001 will display ‘Standard Delay’ the first time it is programmed. All other zones (002
through 256) are instant zones by default.
Standard delay zones have an entry and exit delay. The exit delay starts as soon as the panel is armed. The
loop may be opened and closed during the delay time without causing an alarm. After the exit delay time
has expired, opening the loop will start the entry delay timer. During the entry delay time, the keypad will
sound steadily to advise the user that the system should be disarmed. If the panel is disarmed before the
entry time expires, no alarm will be generated. Program the entry and exit delay times in the Area Times
section.
This zone type is identical to the Standard Delay type zone with one exception - zones of this type can be
force armed (i.e. the system can be armed with this zone in an unrestored or open state). Force arming will
not be shown to the user. When the zone restores (closes), it will become armed with the rest of the area.
Once the zone is armed, an alarm will occur if it is violated again.
NOTE: Force arm delay zones will never cause a “Warning-Security Reduced” message.
The auxiliary delay zone operates the same way as the standard delay zone. However different entry/exit
times may be programmed. This is useful when a system has two delay zones, each requiring a different
entry/exit time. Program the auxiliary entry and exit delay times in the Area Times section.
If the zone is violated, it will activate instantly after the area is armed and the exit delay has expired.
The zone will follow the entry time of a delay zone. If no delay zone has been tripped the zone will activate
instantly. Zones of this type can be force armed (i.e. the system can be armed with this zone in an unrestored
or open state). Force arming will not be shown to the user. When the zone restores (closes), it will become
armed with the rest of the area. Once the zone is armed, an alarm will occur if it is violated again.
NOTE: Interior zones will never cause a “Warning-Security Reduced” message.
ZONE TYPEZONE TYPE
ZONE TYPEZONE TYPE
ZONE TYPE
(1)(1)
(1)(1)
(1)
AUXILIARY DELAYAUXILIARY DELAY
AUXILIARY DELAYAUXILIARY DELAY
AUXILIARY DELAY
(02)(02)
(02)(02)
(02)
STANDARD DELAYSTANDARD DELAY
STANDARD DELAYSTANDARD DELAY
STANDARD DELAY
(00)(00)
(00)(00)
(00)
INSTANTINSTANT
INSTANTINSTANT
INSTANT
(03)(03)
(03)(03)
(03)
ZONE LABELZONE LABEL
ZONE LABELZONE LABEL
ZONE LABEL
(0)(0)
(0)(0)
(0)
FORCE ARM DELAYFORCE ARM DELAY
FORCE ARM DELAYFORCE ARM DELAY
FORCE ARM DELAY
(01)(01)
(01)(01)
(01)
INTERIORINTERIOR
INTERIORINTERIOR
INTERIOR
(04)(04)
(04)(04)
(04)