DSC PC6010 Installationshandbuch Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
28
SYSTEM AREASYSTEM AREA
SYSTEM AREASYSTEM AREA
SYSTEM AREA
EVENT SCHEDULINGEVENT SCHEDULING
EVENT SCHEDULINGEVENT SCHEDULING
EVENT SCHEDULING
Event Scheduling
Event scheduling allows for a variety of timed events to occur on specific dates and times. Openings and
closings can be suppressed during high traffic times, outputs may be programmed to follow date
schedules and areas may be auto-armed and auto-disarmed by specific times programmed in the date
schedule.
Open/Close Suppression will prevent the communication of openings or closings for the areas, following
a programmed date schedule. When an Open/Close Suppression schedule is active, openings or closings
for the selected areas will be logged to the event buffer, but no transmission will be made to the central
station.
There are 99 Open/Close Suppression Schedules. Each is capable of suppressing either openings or
closings for the selected areas, but not both. To suppress both openings AND closings, you must program
two separate Open/Close Suppression schedules.
The following options are programmable for each Open/ Close Suppression schedule:
Open/Close Suppression Toggle
If the Open/Close Suppression schedule is being used to suppress openings, toggle this option to [Y]. If it
is to suppress closings, toggle this option to [N].
Date Schedule
Enter the 2-digit number of the date schedule that will tell the system when to suppress openings or
closings.
Area Toggle
For the areas that are to have the openings or closings suppressed, toggle the option to [Y]
NOTE: Regardless of opening suppression, when an area is disarmed with alarms in memory, the
opening and opening after alarm reporting code will be reported, if programmed.
Example of an Open/Close Suppression schedule:
Open/Close Suppression Schedule 05 is programmed with:
Openings - Y
Sch. # (Date Schedule Number) - 03
Area 1 - Y
Area 2 - Y
All other areas- N
Date Schedule - 03 is programmed with:
Start Time End Time Day Holiday AutoArm AutoDisarm
(HHMM) (HHMM) S M T W T F S 1 2 3 4 Y/N Y/N
Interval 1 0730 0930 N Y Y Y Y Y N N N N N N N
Interval 2 1630 1830 N Y Y Y Y Y N N N N N N N
Intervals 3 - 4 are left unprogrammed.
In this example, Open/Close Suppression schedule 05 will suppress openings for areas 1 and 2, following
Date Schedule 03 (Monday to Friday 7:30AM to 9:30AM and 4:30PM to 6:30PM). In this example Holiday
Schedules and Autoarm/Disarm Schedules are not used.
NOTE: In an opening suppression window, if an area is disarmed with alarms in memory the opening
(or Autodisarming) and opening after alarm will be transmitted. In a opening/closing suppression
window the openings and closings will be logged to the event buffer, but no transmission will be made
for the event.
EVENT SCHEDULINGEVENT SCHEDULING
EVENT SCHEDULINGEVENT SCHEDULING
EVENT SCHEDULING
(07)(07)
(07)(07)
(07)
OPEN/CLOSE SUPPROPEN/CLOSE SUPPR
OPEN/CLOSE SUPPROPEN/CLOSE SUPPR
OPEN/CLOSE SUPPR
(0)(0)
(0)(0)
(0)
Seitenansicht 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 51 52

Kommentare zu diesen Handbüchern

Keine Kommentare